4
Preface
RFID System
Operation Manual
Preface
Meaning of Signal Words
The following signal words and icons are used in this manual to indicate precautions when using the V600-CA5D01 or
V600-CA5D02. The indicated precautions provide information that is vital to safety. Always observe all precautionary
information.
The signal words and icons are as follows:
Meanings of Alert Symbols
Alert Statements in this Manual
Safety Precautions
Indicates a potentially hazardous situation which, if not avoided, will result in minor or
moderate injury, or may result in serious injury or death. Additionally there may be signif-
icant property damage.
Explosion
Indicates the possibility of explosion under specific conditions.
Prohibition
Indicates general prohibitions.
This product is not designed for use in directly or indirectly detecting human bodies in safety-
related applications.
Do not use the product as a sensing device for human protection.
A lithium battery is built into SRAM Data Carriers and may occasionally cause serious injury
due to combustion, explosion, or burning.
Dispose of SRAM Data Carriers as industrial waste and never disassemble, apply pressure
that would deform, heat to higher than 100C, or incinerate SRAM Data Carriers.
A lithium battery is built into SRAM Data Carriers and may occasionally cause serious injury
due to combustion, explosion, or burning.
When replacing the lithium battery, never short-circuit the positive and negative terminals of a
battery or charge, disassemble, apply deforming pressure, or expose the battery to fire.
WARNING
WARNING

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C