EasyManuals Logo

Omron V600 Series User Manual

Omron V600 Series
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
RFID System
Operation Manual
Section 7 Characteristics According to Application Conditions
Section 7
Appendix
155
2)Communications Time Priority Mode (SW4 Pin 1 OFF)
Communications Time with Data Carriers
Calculations
Communications time
(ms)
Reading T=1.8N+79.0
Writing T=7.1N+180.4
N: No. of bytes processed
No. of bytes processed
0 100 200 300
0
500
1000
1500
2000
2500
(AUTO) WRITE
(AUTO) WRITE
Communications time (ms)

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals