70
SECTION 6
Troubleshooting
CIDRW System
User’s Manual
SECTION 6
Troubleshooting
Amplifier Unit Error
Check the status of the indicators after transmission of the test command.
After taking appropriate corrective action, restart the Amplifier Unit, send the test command again and
check again.
If There Is No Response to the Command:
Check the status of the indicators after transmission of the test command.
After taking appropriate corrective action, restart the Amplifier Unit, send the test command again and
check again.
If There Is a Response to the Command:
Check the status of the indicators after transmission of the test command.
After taking appropriate corrective action, restart the Amplifier Unit, send the test command again and
check again.
RUN COMM NORM ERROR Main check points
The Amplifier Unit may be damaged.
Influence of background noise (change installation position)
Amplifier Unit power supply
If the error cannot be resolved after checking, the Amplifier Unit
may be damaged.
RUN COMM NORM ERROR Main check points
Pleas establish the connection between the PC and the Ampli-
fier Unit again, because the TCP/IP connection may be dis-
connected.
Connection and wiring of the cable between the host device
and Amplifier Unit
Routing of each cable (influence of background noise)
If the error cannot be resolved after checking, the Amplifier Unit
may be damaged.
Connection and wiring of the cable between the host device
and Amplifier Unit
Routing of the cables (influence of background noise)
There is a mistake in the command format (number of charac-
ters, character code, etc.)
RUN COMM NORM ERROR Main check points
There is a mistake in the command format (number of charac-
ters, character code, etc.).
By an interruption of the power supply, the memory may be dam-
aged.
(Lights once)
(Lights once)

Other manuals for Omron V640 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V640 Series and is the answer not in the manual?

Omron V640 Series Specifications

General IconGeneral
BrandOmron
ModelV640 Series
CategoryAmplifier
LanguageEnglish

Related product manuals