DV11 / DVD100 / U2 / U3
4-1
Chapter 4
Function Test & Alignment Procedure
4-1 Test Equipment Needed
- HDTV Source (480P, 720P, 1080i)
- Minolta CL-100
- Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
- After changing parts, check the information below.
4-2 Service Mode
1. Turn on the projector and input the signal
2. Do the following actions sequentially to get into service mode
(1) Press power > left > left > up simultaneously.
4-3 OSD Reset
default setting. The following actions will allow you to erase all end-users' settings and
restore the default setting:
(1) Please get into OSD menu.