9 ENVIRONMENTAL AND EMC
9.1 Recommended Operating Conditions
Temperature: 0
o
C to 40
o
C
Humidity (non-condensing) 5% to 95%
9.2 Storage
Temperature -25
o
C to +85
o
C
Humidity 0% to 95%
9.3 CE and FCC Compliance
CE: This product complies with the requirements of 2004/108/EC Electromagnetic Compatibility
Directive, and 2006/95/EC Low Voltage Directive. Compliance is to EN55022 Class A.
FCC: WARNING: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
interference to radio communications. Operation of this equipment in a residential area is likely
to cause interference in which case the user will be required to correct the interference at their
own expense.
The user is cautioned that changes and modifications made to the equipment without approval of the
manufacturer could void the user’s authority to operate this equipment.
It is suggested that the user use only shielded and grounded signal cables to ensure compliance with
FCC rules.
9.4 PAT Testing
Earth continuity testing under PAT regulations shall be done to the product with 8A or 10A only. A test
with 25A may damage the product.
Since this unit is classified as an IT equipment, according to the IEE Code of Practice, the test can also
be performed with 20-200mA. If this method is not available, and a high current test is to be used
instead, a 8A or 10A test is also acceptable (a minimum of 1.5 times of the internal 5A fuse).
Always connect the test lead (mains earth) to the metal chassis. DO NOT CONNECT to the connectors
of the rear panel (signal earth), because you may damage the unit beyond repair. This type of damage
is not covered by warranty.