Connection
25
7 Connection
This chapter explains how to connect the driver and motor, I/O signals, and power supply, as well as the grounding
method.
7.1 Connection example
The connection example below shows an example of a electromagnetic brake type single-phase 100 to 120 V driver
where the built-in power supply and supplied external potentiometer are used to set the speed. Refer to the applicable
pages for details.
Motor power connector
Connect to CN2
Electromagnetic brake
connector
Connect to CN1
2
Motor signal connector
Connect to CN4
SW2-2㻦㻌Set this switch when setting the speed
externally.
ON: The supplied external potentiometer or external
DC voltage is used to set the speed at 5 VDC
(factory setting).
OFF: DC voltage is used to set the speed at 10 VDC.
SW2-1: Set the I/O signal power supply.
ON: When relays, switches, etc., are used to control
the operation (driver's built-in power supply).
OFF: When external DC voltage from a programmable
controller, etc., is used to control the operation
(factory setting).
SW1-1: Not use.
Connection
cable
Motor
cable
For 200 V specificaion;
Single-phase 200 to 240 V
-
15 to +10% 50/60 Hz
Three-phase 200 to 240 V
-
15 to +10% 50/60 Hz
Stop mode selection input
ALARM-RESET input
Regeneration resistor thermal input
External
potentiometer
(supplied)
Clockwise rotation input
Counterclockwise rotation input
Speed setting selectionInternal/
External
Input common
1
Input common (0 V)
Power supply connection
SW1-2: Set the FBLcompatible mode.
ON: The FBL
compatible mode is enabled.
OFF: The FBL
compatible mode is disabled
(factory setting).
1IN-COM0
2FWD
3REV
5M0
6ALARM-RESET
7MB-FREE
8TH
9VH
10VM
11VL
12IN-COM1
13SPEED-OUT+
14SPEED-OUT
-
15ALARM-OUT1+
16ALARM-OUT1
-
4STOP-MODE
PE
PE
Single-phase 100 to 120 V
-
15 to +10% 50/60 Hz
3
2
3
150 °C
2
1
1
SPEED-OUT output
ALARM-OUT1 output
GND
GND
Electromagnetic brake release input
2
*1
Connection is not necessary if the built-in power supply is used.
*2
Connection is necessary only when using an electromagnetic brake motor.
p.27
p.27
p.26
p.44
p.39
p.29
p.29
p.29
p.39
p.28