7.2 Connecting the power supply
Connect the power cable to the Power supply input terminal (TB1) on the driver.
Tightening torque: 1.0 N·m (8.8 lb-in)
The product does not come with a power cable. It must be supplied by the user.
z
Single-phase 100-120 V
Connect the live side to terminal L, and the neutral side to
terminal N.
L
N
z
Single-phase 200-240 V
Connect the live side to terminal L, and the neutral side to
terminal N.
L
N
z
Three-phase 200-240 V
Connect the R, S and T phase lines to the L1, L2 and L3
terminals, respectively.
R
S
T
z
Power connection terminal and cable
Applicable crimp terminal: Round crimp terminal with insulation cover
Thread size of terminal: M3.5
Applicable lead wire: AWG18 to 14 (0.75 to 2.0 mm
2
)
Temperature rating of lead wire: 60 °C, 60 or 75 °C, or 75 °C
(140 °F, 140 or 167 °F, or 167 °F)
Conductive material: Use only copper wire.
3.8 (0.15)
or less
7.2 (0.28) or less
6.2 (0.24) or less
after crimping
Ø3.6 (0.14)
or more
Unit: mm (in.)
Circuit breaker
Be sure to connect a circuit breaker to the power line of the driver to protect the primary circuit.
Rated current of protective device: Single-phase input 10 A, three-phase input 5 A
Circuit breaker: Mitsubishi Electric Corporation NF30
7.3 Grounding
Grounding the motor
Connect the Protective Earth Terminal on the motor to the ground near the
motor. Minimize the wiring length of the ground cable.
Tightening torque: 0.8 to 1.0 N·m (7.0 to 8.8 lb-in)
z
Ground terminal and cable
Applicable crimp terminal: Round crimp terminal with insulation cover
Thread size of terminal: M4
Applicable lead wire: AWG18 to 14 (0.75 to 2.0 mm
2
)
4.8 (0.19) or less
9.5 (0.37) or less
Ø4.1 (0.16) or more
Unit: mm (in.)