Extended functions
−
47
−
9 Extended functions
The following functions can be extended using the
OPX-2A
or
MEXE02
.
For details, refer to the operating manual for each product.
•
A maximum of eight speeds can be set.
•
The torque can be limited.
•
The assignments of I/O signals can be changed.
•
The speed, alarm code and load factor can be displayed.
•
I/Os can be monitored.
•
Warnings can be output.
•
Test operation can be performed.
•
Data can be copied.
Example of operation pattern with maximum eight speed settings
ON
OFF
ON
OFF
FWD input
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
M1 input
ON
OFF
M2 input
ON
M0 input
Motor operation
10 Inspection
It is recommended that the items listed below be inspected regularly after motor operation. If any abnormality is
found, stop using the motor and call our Technical Support Line.
Note
•
Never measure insulation resistance or conduct a dielectric strength test with the motor and
driver connected. Doing so may damage the motor/driver.
•
The driver uses semiconductor elements, so handle it with due care. Electrostatic discharge can
damage the driver.
Inspection items
Conrm that:
•
The motor/gearhead mounting screws are not loose.
•
The bearing (ball bearing) and other parts of the motor are not generating noise.
•
The bearing (ball bearing) and gear meshing parts of the gearhead are not generating noise.
•
The motor/gearhead output shaft is not misaligned with the load shaft.
•
The cables are free from damage or stress and are securely connected to the driver.
•
The openings in the driver are not blocked.
•
The driver mounting screws and power connection terminal screws are not loose.
•
The power elements and smoothing capacitors in the driver are not generating an abnormal smell or having
abnormalities.