22
6.9 Installing the regeneration unit (accessory)
Install the accessory regeneration unit
EPRC-400P
(sold
separately) in a location where heat dissipation capacity
equivalent to a level achieved with a heat sink [made of
aluminum, 350×350×3 mm (13.78×13.78×0.12 in.)] is
ensured.
Afx the
EPRC-400P
on a smooth metal plate offering high
heat conductivity, using two screws (M4, not supplied).
Regeneration
unit
EPRC-400P
Screw (M4)
165 (6.50)
Mounting hole dimension
[unit: mm (in.)]
Ø4.2
+ 0.3
0
+ 0.012
0
(0.165 )
6.10 Installing the external potentiometer (supplied)
Insert the external potentiometer as shown below.
Nut
Tightening torque:
0.45 N·m (3.9 lb-in)
Setscrew (M4)
Tightening torque:
0.4 N·m (3.5 lb-in)
Ø3 (Ø0.12)
7.5
±0.4 (0.30±0.02)
Ø10 (Ø0.39)
Dial
Toothed washer
Dial plate
Mounting plate
Insulation
sheet
Variable resistor
Reference mounting hole dimensions
[Unit: mm (in.)]
Soldering the variable resister terminal and the lead wires
Cover a heat-shrinkable tube over the soldered part to insulate.
Soldering condition: 235 °C (455 °F), less than 5 sec.
Lead wire
Lead wire
Terminal
Heat-shrinkable tube
Dial
Variable resistor
Solder (Pass the lead wire
through the terminal hole and
give it two or three turns.)