Installation
−12−
6 Installation
This chapter explains the installation location, installation methods of the motor and driver, and how to install a load
and an external potentiometer. The installation and wiring methods in compliance with the EMC Directive are also
explained.
6.1 Installation location
The motor and driver are designed and manufactured to be incorporated in equipment.
Install them in a well-ventilated location that provides easy access for inspection. The location must also satisfy the
following conditions:
•
Inside an enclosure that is installed indoors (provide vent holes)
•
Operating ambient temperature 0 to +40 °C (+32 to +104 °F) (non-freezing)
•
Operating ambient humidity 85% or less (non-condensing)
•
Area not exposed to direct sun
•
Area free of excessive amount of dust, iron particles or the like
•
Area free of excessive salt
•
Area that is free of explosive atmosphere or toxic gas (such as sulfuric gas) or liquid
•
Area not subject to splashing water (rain, water droplets), oil (oil droplets) or other liquids
•
Area not subject to continuous vibration or excessive shocks
•
Area free of excessive electromagnetic noise (from welders, power machinery, etc.)
•
Area free of radioactive materials, magnetic elds or vacuum
•
Altitude Up to 1000 m (3300 ft.) above sea level