How to use MEXE02
−44−
10.4 Monitor
Unit information monitor
The unit information monitor is provided in the
MEXE02
.
Using this monitor function can check the product information such as the number of times and the elapsed time
that the main power supply is turned on and the setting status of the driver switches (SW1, SW2, SW3). The set values
of parameters related to operation and communication can also be checked.
1. Start "Unit information monitor."
2. Click "Start the Unit information monitor."
The unit information monitor starts.
The switch setting status is shown as follows.
ON (green)
OFF (white)
Switches not possible to monitor (gray)
3. To exit the unit information monitor, unselect "Start the Unit information monitor."
How to view the unit information monitor window
The status when the unit information monitor is started is displayed.
Area Item Description
Product information area
Ver. Monitors the software version used.
Main power supply
count
Monitors the number of times that the main power supply of
the driver is turned on.
Main power supply time
Monitors the integrated value of the main power supply time
of the driver.
Driver setting value area
Speed response
selection
*1
Monitors the speed response mode presently set.
Motor rotation direction
selection
*2
Monitors the setting of the "Motor rotation direction
selection" parameter presently set.
Operation input mode
selection
*2
Monitors the setting of the "Operation input mode selection"
parameter presently set.
Switch setting area
Basic setting (SW1)
Monitors the ON-OFF status of the basic function switch
(SW1).
Communication setting
(SW2)
Monitors the ON-OFF status of the communication function
switch (SW2).
Address number setting
(SW3)
Monitors the setting status of the address number setting
switch (SW3).
Communication setting area
*1
Protocol Monitors the communication protocol presently set.
Address number Monitors the address number presently set.
Transmission rate Monitors the transmission rate presently set.
Communication parity
Monitors the communication parity (for Modbus) presently
set.
Communication stop bit
Monitors the communication stop bit (for Modbus) presently
set.
Transmission waiting
time
Monitors the transmission waiting time (for Modbus)
presently set.
*1∗
To update the setting having changed to the driver, it is required to turn on the power supply again.
*2∗
To update the setting having changed to the driver, it is required to execute Conguration or to turn on the power supply again.