Connection
−23−
7 Connection
This chapter explains how to connect the driver with the motor, the power supply cable, and I/O signals.
BLV510
Be sure to use the connection cable (included) for the exclusive use of the
BLV510
product to connect the motor and
driver.
The motor cable cannot be connected to the driver directly. It is required to convert the connector of the motor cable
using the connection cable (included) for the exclusive use of the
BLV510
product.
Maximum extension distance between the motor and driver: 1.5 m (4.9 ft.) [including 0.5 m (1.6 ft.) of the motor cable]
Required
Driver
DC power supply
Motor cable
Motor
RS-485 communication cable
MEXE02
or
OPX-2A
I/O signal cable
Grounding
+
-
24 VDC±10%
Connection cable
[0.2 m (0.66 ft.) or 1 m (3.3 ft.)]
BLV620
,
BLV640
Maximum extension distance between the motor and driver: 3.5 m (11.5 ft.) [including 0.5 m (1.6 ft.) of the motor cable]
Driver
DC power supply
RS-485 communication cable
MEXE02
or
OPX-2A
I/O signal cable
+
-
BLV620 :
24 VDC±10%
BLV640 :
48 VDC±10%
Motor cable
Moto
r
Grounding
Connection cable
[1 m (3.3 ft.), 2 m (6.6 ft.),
3 m (9.8 ft.)]
The motor cable can be connected to the driver directly.