EasyManua.ls Logo

Oriental motor BLVD20KM - Status monitor

Oriental motor BLVD20KM
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
How to use MEXE02
−45−
Status monitor
The present motor status such as the motor feedback speed or load factor, the setting method of operation data, and
the present status of the setting value can be checked with the monitor.
1. Start the "Status monitor."
2. Click "Start Status Monitor."
Status monitor starts.
3. To exit the status monitor, unselect "Start Status Monitor."
How to view the status monitor window
Item Description
Command speed (motor output shaft) Monitors the command speed of the motor.
Load factor
Monitors the motor output torque as a load factor (The load factor is a value
when the rated torque is being 100%).
Inverter voltage Monitors the present voltage value inside the driver.
Feedback speed (motor output shaft) Monitors the feedback speed of the motor.
Feedback speed (gearhead output shaft) Monitors the feedback speed converted by the set speed reduction ratio.
Conveyor transfer speed Monitors the conveyor transfer speed.
Selection number Monitors the operation data number presently selected.
Rotation speed setting method Monitors the setting method of the rotation speed presently set.
Acceleration time setting method Monitors the setting method of the acceleration time presently set.
Deceleration time setting method Monitors the setting method of the deceleration time presently set.
Torque limiting value setting method Monitors the setting method of the torque limiting value presently set.
Rotation speed setting value Monitors the rotation speed presently set.
Acceleration time setting value Monitors the acceleration time presently set.
Deceleration time setting value Monitors the deceleration time presently set.
Torque limiting setting value Monitors the torque limiting value presently set.
Rotation speed
Monitors the value obtained by converting the setting values of the internal
potentiometer (VR1, VR2, VR3) and the external analog setting device to the
rotation speed, acceleration time/deceleration time, and torque limiting value.
Acceleration time/Deceleration time
Torque limiting value
Input voltage
*
Monitors the voltage of the external analog setting device presently input.
*
If the basic function switch (SW1-No.2) is set to ON (0 to 10 VDC), half the voltage is monitored.