How to use MEXE02
−49−
Waveform monitor
The motor rotation speed or the status of I/O signals can be checked in a waveform format.
1. Start the "Waveform monitor."
2. Click "Start Waveform Monitor."
The buttons on the window are enabled, allowing you to prepare for measurement of the waveform monitor.
1
Sets the Pos (trigger position), Level, CH, Mode, and Edge (detection condition) that are used when a waveform is
measured.
For "CH," only those CHs displayed on
⑨
can be used.
2
RUN: This button is used to start measurement.
STOP: This button is used to stop measurement.
3 Sets the measurement time range (width).
4
Sets the display method for CH5 to CH12.
Scale: Selects the display size from 1/1 (100%), 1/2 (50%), or 1/4 (25%).
Signal name: Shows or hides the signal name.
5 Shows the CH setting window.
6 Shows or hides measures for measurement. Also, selects the CH to be measured.
7 Shows or hides each CH.
8
When the display position of the waveform drawn on the window is moved, the CH items selected here can be
moved all together.
9 Measurement results are drawn in this area.
10 Copies the waveform presently shown to the clipboard.
11 Saves the waveform presently shown to an external le.
12 Reads the setting for measurement from "Favorites."
13 The setting for measurement can be saved as "Favorites."
7 8
3
1
2 54 6 10 11 12 13
9
2