Setting contents of MEXE02
−55−
Parameter name Setting range Factory setting Update Ref.
I/O function selection
NET-OUT0 output function selection
Not used
FWD_R (START/STOP_R)
*
REV_R (RUN/BRAKE_R)
*
STOP-MODE_R (FWD/REV_R)
*
MB-FREE_R, HMI_R, M0_R, M1_R
M2_R, ALARM-OUT1, WNG
MOVE, TLC, VA, S-BSY
ALARM-OUT2, MPS, DIR
M0_R
C P.58
NET-OUT1 output function selection M1_R
NET-OUT2 output function selection M2_R
NET-OUT3 output function selection FWD_R (START/STOP_R)
*
NET-OUT4 output function selection REV_R (RUN/BRAKE_R)
*
NET-OUT5 output function selection STOP-MODE_R (FWD/REV_R)
*
NET-OUT6 output function selection WNG
NET-OUT7 output function selection ALARM-OUT1
NET-OUT8 output function selection S-BSY
NET-OUT9 output function selection Not used
NET-OUT10 output function selection Not used
NET-OUT11 output function selection Not used
NET-OUT12 output function selection ALARM-OUT2
NET-OUT13 output function selection MOVE
NET-OUT14 output function selection VA
NET-OUT15 output function selection TLC
Alarm and warning
Undervoltage alarm latch Disable, Enable Disable C
P.60
Undervoltage warning level 0.0 to 48.0 [VDC]
24 VDC type: 21.6
48 VDC type: 43.2
A
Undervoltage warning function Disable, Enable Enable
Overload warning level 50 to 100 [%] 100
Overload warning function Disable, Enable Enable
Test operation and
display
JOG operation speed 0, 80 to 1000 [r/min] 300
A
P.60
JOG operation torque 0 to 200 [%] 200
Data setter speed display Signed, Absolute value Signed
Data setter edit Disable, Enable Enable D
Operation setting
Data setter initial display
Operating speed, Conveyor transfer
speed, Load factor, Operation data
number, Top screen of monitor mode
Operating speed D
P.60
Analog input signal selection Mode 0 to 5 Mode 0
C
Prevention of operation at power-
on alarm
Disable, Enable Disable
Electromagnetic brake action at
alarm
Hold after coasting stop
Hold immediately
Hold immediately
Operation input mode selection 2-Wire mode, 3-Wire mode 2-Wire mode
Communication
Communication timeout 0 to 10000 [ms] (0: Not monitored) 0
A
P.62
Communication error alarm 1 to 10 [times] 3
Communication parity None, Even number, Odd number Even number
DCommunication stop bit 1 bit, 2 bits 1 bit
Transmission waiting time 0.0 to 1000.0 [ms] 10.0
∗*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be applied.