- 68 - - 69 -
3.2. Power Off
- Command for Power Off : Stand-by status
- CMD : 0x41
- It is available only during Power On (Operative) status.
- Send to MPDP
A. Normal command
STX CMD Length
Data
ETX
ID Master
Value 0x02 0x41 0x02 Variable 0x01 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
B. Broadcast command
STX CMD Length Data: ID ETX
Value 0x02 0x41 0x01 0x00 0x03
* All PDP will do the same operation simultaneously. But, there will be no return communication. (One way command)
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 0x41 0x02 Variable 0x01 Variable 0x03
* ID range (Program): 0x01(1) ~ 0xFF(255)
* Check sum: execute "Not" operation after adding all the values in "STX~Data" area.
3.3. Power off for Afterimage Mitigation
- Command for Power Off : Stand-by status
- CMD : 0x89
- It is available only during Power On (Operative) status.
- Send to MPDP
A. Normal command
STX CMD Length
Data
ETX
ID Master Mode Time Duration
Value 0x02 0x89 0x04 Variable 0x01 Variable Variable 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
* Mode : Full White Pattern(0x01), White Bar Scan(0x02), Default(0x00)
* Time Duration : 0x00 : No Display, 0x01: 5 Minute , 0x03: 15 Minute, 0x06: 30 Minute, 0x0C : 1 Hour...0xF0: 20 Hour)
B. Broadcast command
STX CMD Length
Data
ETX
ID Mode Time Duration
Value 0x02 0x89 0x03 0x00 Variable Variable 0x03
* All PDP will do the same operation simultaneously. But, there will be no return communication. (One way command)
* Mode : Full White Pattern(0x01), White Bar Scan(0x02), Default(0x00)
* Time Duration : 0x00 : No Display, 0x01: 5 Minute , 0x03: 15 Minute, 0x06: 30 Minute, 0x0C : 1 Hour...0xF0: 20 Hour
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 0x89 0x02 Variable Variable Variable 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
* Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
3.4. Multi-Scale
- Command for expanding the screen of MPDP.
- It is available only on Power On (Operative) status.
- CMD: 0XDD (DVI), 0XDE(PC), 0XE2(VIDEO)
- Send to MPDP
A. Normal command
STX CMD Length
Data
ETX
ID Master XY P
Value 0x02 Variable 0x04 Variable 0x01 Variable Variable 0x03
* ID range (Program): 0x01(1) ~ 0xFF(255)
* XY: The number of horizontal axis (X)/ the number of vertical axis(Y); upper 4 bits -X (Max:15), Lower 4bits - Y (Max: 15)
* P: the location of expanded screen
B. Broadcast command
STX CMD Length
Data
ETX
ID XY S X
Value 0x02 Variable 0x04 0x00 Variable Variable Variable 0x03
* ID: 0x00
* XY: The number of MPDP sets in horizontal line(X), the number of MPDP sets in vertical line(Y)
The top 4bits - X (Max: 15), the bottom 4bits - Y (Max: 15)
1:1 screen ratio (Full screen) is “0x11”
* S: The ID of MPDP to be expanded in top left position, 1:1 screen ratio (Full screen) is “0x00”
* X: The number of all X axis line, 1:1 screen ratio (Full screen) is “0x01”
* Make all PDP do the same operation. But, there will be no return communication. (One way command)
Broadcast command: e.g.) In case of 5x5 MPDP formation
ⓐ ⓑ ⓒ ⓓ ⓔ
1 4
13 11
ⓐ
0x02(STX) 0xDD(CMD) 0x04(Length) 0x00(ID) 0x33(XY) 0x01(S) 0x05(X) 0x03(ETX)
ⓑ
0x02(STX) 0xDD(CMD) 0x04(Length) 0x00(ID) 0x33(XY) 0x0D(S) 0x05(X) 0x03(ETX)
ⓒ
0x02(STX) 0xDD(CMD) 0x04(Length) 0x00(ID) 0x22(XY) 0x04(S) 0x05(X) 0x03(ETX)
ⓓ
0x02(STX) 0xDD(CMD) 0x04(Length) 0x00(ID) 0x41(XY) 0x0B(S) 0x05(X) 0x03(ETX)
ⓔ
0x02(STX) 0xDD(CMD) 0x04(Length) 0x00(ID) 0x11(XY) 0x00(S) 0x01(X) 0x03(ETX)
OPM-4260 | OPM-4260R
Innitely Expandable