- 78 - - 79 -
A. Normal Command
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
B. Broad-Cast Command
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
C. Frequency/Phase/Line-Start/Pixel-Start -tracking (Normal Command): Adjusting PC (RGB) screen manually.
STX CMD Length
Data
ETX
ID Master Tracking Value
Value 0x02 Variable 0x03 Variable 0X01 Variable 0x03
D. Frequency/Phase/Line-Start/Pixel-Start -tracking (Broad-Cast Command): Adjusting PC (RGB) screen manually.
STX CMD Value Length
Data
ETX
ID Tracking Value
Value 0x02 Variable 0x02 0x00 Variable 0x03
* ID range (Program): 0x01(1) ~ 0xFF(255)
* Broad-cast: All PDP sets will execute the same command, when the ID is 0x00. No response (One way command)
* "Get Tracking Value" command cannot be used for "Broad-cast" command.
- Frequency value range: 77(0x4D) ~ 177(0xB1) / Real Value(-50 ~ +50) / Real Value + 127(0x7F)
- Phase value range: 127(0x7F) ~ 190(0xBE) / Real Value(0 ~ +63) / Real Value + 127(0x7F)
- Line Start value range: 104(0x68) ~ 137(0x89) / Real Value(-23 ~ +10) / Real Value + 127(0x7F)
- Pixel Start value range: 77(0x4D) ~ 167(0xA7) / Real Value(-50 ~ +40) / Real Value + 127(0x7F)
- Receive from MPDP
A. Auto-tracking, Frequency/Phase/Line-Start/Pixel-Start-tracking
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03
B. Get Tracking Values
STX CMD Length
Data
Check Sum ETX
ID Master Tracking Value
Value 0x02 Variable 0x06 Variable 0X01 … Variable 0x03
Frequency Phase LineStart PixelStart
Variable Variable Variable Variable
* ID range(Program): 0x01(1) ~ 0xFF(255)
* Tracking Value
- Frequency value range : 77(0x4D) ~ 177(0xB1) / Real Value(-50 ~ +50) / Real Value + 127(0x7F)
- Phase value range : 127(0x7F) ~ 190(0xBE) / Real Value(0 ~ +63) / Real Value + 127(0x7F)
- Line Start value range : 104(0x68) ~ 137(0x89) / Real Value(-23 ~ +10) / Real Value + 127(0x7F)
- Pixel Start value range : 77(0x4D) ~ 167(0xA7) / Real Value(-50 ~ +40) / Real Value + 127(0x7F)
* Check Sum: execute "Not" operation after adding all the values in "STX~Data" area.
3.18. Sync Correction
- It is the command for reducing the ashing effect.
1) Sync Correction Mode
- User can select or switch the Sync Control mode; “Auto” or “Manual.”
- CMD: 0xC9
- It is functioning only for Power On status.
- Send to MPDP
A. Normal command
STX CMD Length
Data
ETX
ID Master Mode
Value 0x02 0xC9 0x03 Variable 0x01 Variable 0x03
* ID range (Program): 0x01(1) ~ 0xFF(255)
* Mode: Manual (0x00), Auto (0x01)
B. Broadcast command
STX CMD Length
Data
ETX
ID Mode
Value 0x02 0xC9 0x02 0x00 Variable 0x03
* Execute the same command for all PDP sets. No response will be made. (One-way command)
* Mode : Manual(0x00), Auto (0x01)
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 0x89 0x02 Variable 0x01 Variable 0x03
* ID range (Program) : 0x01(1) ~ 0xFF(255)
* Check Sum : Add the values from STX to Data and execute the “NOT” operation.
2) Sync Correction Time Write
- Sync Correction Time for MPDP can be congured. It is only available for Manual mode.
- CMD : 0x6A
- Send to MPDP
A. Normal command
STX CMD Length
Data
ETX
ID Master Control Data
Value 0x02 0x6A 0x09 Variable 0X01 Variable 0x03
BIT Mode
Read/Write Mode
Address
TimeData(4 Bytes)
0x04 0x00 0xA2 Variable
* ID range (Program) : 0x01(1)~ 0xFF(255)
* Control Data
-Time Data : 0x00000000 ~ 0x000000FF (0~255, 4Bytes)
OPM-4260 | OPM-4260R
Innitely Expandable