- 80 - - 81 -
B. Broadcast command
STX CMD Length
Data
ETX
ID Control Data
Value 0x02 0x6A 0x08 0x00 Variable 0x03
BIT Mode
Read/Write Mode
Address
TimeData(4 Bytes)
0x04 0x00 0xA2 Variable
* Execute the same command for all PDP sets. No response will be made. (One-way command)
* Control Data
-Time Data : 0x00000000 ~ 0x000000FF (0~255, 4Bytes)
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 0x6A 0x02 Variable 0x01 Variable 0x03
* ID range (Program) : 0x01(1) ~ 0xFF(255)
* Check Sum : Add the values from STX to Data and execute the “NOT” operation
3) Sync Correction Read
- The information for Sync Control related conguration and changes can be read.
- CMD : 0x6A
- Send to MPDP
A. Normal command
STX CMD Length
Data
ETX
ID Master Control Data
Value 0x02 0x6A 0x05 Variable 0X01 Variable 0x03
BIT Mode
Read/Write Mode
Address
0x04 0x01 0xA2
* ID range (Program) : 0x01(1)~ 0xFF(255)
* It is not available for Broadcast command.
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master Control
Value 0x02 0x6A 0x0A Variable Variable Variable Variable 0x03
BIT Mode
Read/WriteMode
Address
Time Data(4 Bytes) Manual/ Auto Mode
0X04 0X01 0XA2 Variable Variable
* ID range (Program) : 0x01(1) ~ 0xFF(255)
*Slave / Master : Master(0x01)
*Control
- Time Data : 0x00000000 ~ 0x000000FF (0~255, 4Bytes), In case of Auto Mode, the response will be 0x00000000(0).
- Manual /Auto Mode : 0(0x00) for Manual , 1(0x01) for Auto
*Check Sum : Add the values from STX to Data and execute the “NOT” operation
3.19. White Balance Control
- Command for adjusting Gain R/G/B and Offset R/G/B for White balance
- CMD: 0xAC (Gain R), 0xAD (Gain G), 0xAE (Gain B), 0xB0 (Offset R), 0xB1 (Offset G), 0xB2 (Offset B)
- The adjusted value is not applied during Stand-by or No-signal status. MPDP must be operating status and
there must be the input signal of each mode.
- To apply the same conguration to all MPDP sets, the "ID" area value can be set as "0x00." However,
considering differences between sets, individual adjustment for white balance is recommended.
- Send to MPDP
A. Normal Command
STX CMD Length
Data
ETX
ID Master Control
Value 0x02 Variable 0x03 Variable 0x01 Variable 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
* Control: “0 (0x00)” ~ “255 (0xFF)”
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0x01 Variable 0x03
* ID range (Program): 0x01(1) ~ 0xFF(255)
* Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
3.20. Firmware Default Set (Picture Control Data)
- Initialize the PDP set. All the settings will be returned to the initial condition prior to the adjustment in the
factory. Pre-programmed value will be applied.
- CMD : 0x81
- It is available only on Power On (Operative) status.
- Since previous Picture Control Data will be lost with this command. High caution is required.
- Send to MPDP
STX CMD Length
Data
ETX
ID Master
Value 0x02 0x81 0x02 Variable 0x01 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
* It is not applicable as "Broad-cast" command.
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 0x81 0x02 Variable 0x01 Variable 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
* Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.