Do you have a question about the ORTEC DSPEC 502A and is the answer not in the manual?
Brand | ORTEC |
---|---|
Model | DSPEC 502A |
Category | Measuring Instruments |
Language | English |
Procedures for returning instruments for repair, including authorization and shipping.
Explains ballistic deficit and how to adjust flattop duration for improved resolution.
Details how the Resolution Enhancer corrects for charge trapping in germanium detectors.
Describes the Enhanced Throughput Mode for optimal pulse processing and throughput.
Explains the LFR filter for reducing low-frequency noise in spectrometry.
Explains the Zero Dead-Time (ZDT) mode of operation for accurate dead-time correction.
Lists the necessary host computer and ORTEC software requirements for operation.
Describes the front panel components and interface of the DSPEC 50.
Explains the functionality and navigation of the touchscreen interface.
Details the rear panel connectors and ports.
Instructions for changing fuses and line voltage settings.
Step-by-step guide for replacing fuses in the instrument.
Procedure for adjusting the line voltage selector card.
Verifying correct line voltage, fusing, and power cord for the region.
Guide to installing the CONNECTIONS driver update kit.
Instructions for installing MAESTRO or other spectroscopy software.
Steps for connecting the instrument to a network or computer.
Details on establishing an Ethernet connection, including DHCP and static IP.
Instructions for connecting the instrument via USB.
Guide to running MCB Configuration for instrument communication.
Controls for gain, baseline restore, and preamplifier type.
Guide to using the automatic optimization feature for settings.
Advanced shaping controls and virtual oscilloscope access.
Controls for LFR filter, noise rejection, and throughput mode.
Step-by-step guide for training the Resolution Enhancer feature.
Controls for Gate, ZDT Mode, Conversion Gain, and Discriminators.
Settings for gain and zero stabilization of the spectrum.
Controls for setting and monitoring the high voltage supply.
Configuration of acquisition presets like Real Time and Live Time.
Setting up minimum detectable activity presets.
Guidance on setting the rise time for optimal results.
Accessing and using the instrument's web interface.
Explains Dead-Time and Zero Dead-Time corrections.
Step-by-step guide to assigning static IP addresses.
Common issues and solutions when MAESTRO software fails to connect.
Addresses problems encountered during static IP address configuration.
Procedure for resetting a lost password for configuration screens.