9.2 Entering observer texts
(extended Observer function)
Requirements
The "Extended observer (store and transmit number)" option in the
"Display/Observer" function block is activated (refer to online help).
In the "Display/Observer" function block, observer texts are stored
(refer to online help).
How to enter observer texts for the station:
Press jog shuttle twice. (Between the first and second presses, the LCD display
shows the OTT netDL firmware version.)
The OTT netDL activates the LCD display
and
shows the selection menu (if password protection for the LCD display is
e
nabled ➝ first enter the four-digit password; refer to online help).
Press jog shuttle (Observer). The
LCD display
shows the station name, the sta-
tion number, the current time and, after 2 seconds, the level of the voltage supply.
…
For the measurement site:
Rotate jog shuttle to !.
Press jog shuttle in order to begin the entry of the observer texts.
When a "Manual sensor" is present in the configuration of the OTT net DL unit
(the LCD first shows a selection window): press the jog shuttle (
Observer).
Rotate jog shuttle until the required number/text appears and then press. (The
numbers are not necessarily sorted in ascending order. The row numbers of the
table entries of the observer texts are decisive; refer to online help). By select-
ing the number
0000, freely editable texts can be entered (see below).
Confirm the entry: Press jog shuttle (√). (Cancel: Rotate jog shuttle to ≈ and
press.)
Finish entering observer text: ("Manual sensor" present: first rotate jog shuttle
to the
End position and press) rotate jog shuttle to ≈ and press; then rotate
jog shuttle to the
End position and press. If the jog shuttle is not used for three
minutes, the LCD display shuts off automatically.
… For a channel (sensor):
Press jog shuttle (¥). The
LCD
display shows the screw terminal strip used, the
sensor name/number as well as the instantaneous value of the first channel
(sensor).
Change to the next channel if required: Press (several times) jog shuttle (¥).
After the last channel has been shown, the LCD display shows the first channel
again.
Rotate jog shuttle to the ! position.
Press jog shuttle to begin entering the observer texts.
Rotate jog shuttle until the required number/text appears and then press. (The
numbers are not necessarily sorted in ascending order. The row numbers of the
table entries of the observer texts are decisive; refer to online help). By select-
ing the number
0000, freely editable texts can be entered (see below).
Confirm the entry: Press jog shuttle (√). (Cancel: Rotate jog shuttle to ≈ and
press.)
Finish entering observer text: rotate jog shuttle to ≈ and press (twice); then
rotate jog shuttle to
End position and press. If the jog shuttle is not used for
three minutes, the LCD display shuts off automatically.