Parsivel
Internal errors: 02 Communication error
05 Wire break
External errors: None
SDI sensor and SDI sensor via RS-485
Internal errors: 02 Communication error
05 Wire break: Sensor not responding
External errors: 01 Communication error: Sensor sending fewer (or no)
measured values than indicated
02 Communication error: Sensor sending more
measured values than indicated
03 Over-/underflow: SDI sensor sending "99999"
04 Incorrect SDI-12 address
RS-232-Eingang
Internal errors: 02 Communication error
0
3 over-/underflow
04 Timeout during measurement
05 Wire break
06 A forwarded error message of the connected
"intelligent" sensor is present
External errors: None
21.4 Error messages of the processing modules
Linearization table
Internal errors: 03 Table limits exceeded/underrun
("
No extrapolation" feature enabled)
External errors: None
Q calculation
Internal errors: 03 Table limits exceeded/underrun
("
No extrapolation" feature enabled)
External errors: None