5. Advanced User Guidebook
End and store
Close the keyboard
Switch between
capital and small
Delete the last
character
How to Record/Playback Waveforms
Wave Record function can record the input current wave. You can set the interval
between recorded frames in the range of 1ms~1000s.The max frame number reaches
1000,and you can get better analysis effect with playback and storage function.
Wave Record contains four modes: OFF, Record, Playback and Storage.
Record: To record wave according to the interval until it reaches the end frame set.
Record menu shows as follows:
Menu Setting Instruction
Mode
OFF
Record
Playback
Storage
Close wave record function
Set record menu
Set playback menu
Set storage menu
End frame
Turn the G knob to select the number of frames to
record (11000)
Record mode
FrameSet
Interval
Turn the G knob to select the interval between
recorded frames (1ms1000s)
Refresh
ON
OFF
Refresh wave during recording
Stop refreshing
Operate
Play
Stop
Begin to record
Stop recording
Note:
Both of the waveforms of Channel 1 and Channel 2 will be recorded. If a Channel is
turned off while recording, the waveform of the channel is invalid in the playback
mode.
47