SECTION 5 REMOTE OPERATION
70
5.3 PROGRAM CONTROL
:PROGram:NAME <nn> Command: selects program “nn” for executing, deleting or copying.
nn = <0> to <99>
Query: returns the program number last selected.
:PROGram[:SELected]:DEFine <program>
Command: defines the values stored in program “nn”. Both steady-state and
transient segment parameter names and values may be sent. Program
parameters are defined in the following sections.
NOTE: Only commas may separate the values, NO Carriage Returns or Line
Feeds may separate the values within a single Command.
Query: returns steady-state values of selected program and segment values of
most recently selected segment or multiple segments if specified by a previous
NSEGS parameter. "LAST" is returned with segment data if the segment is the
last segment in the program.
STEADY-STATE OUTPUT PARAMETERS
FORM,<n>,
COUPLing,<s>,
XFMRRATIO,<n.nn>,
FREQuency,<n>,
VOLTage,<n>, see Convention #11.
VOLTage1,<n>,
VOLTage2,<n>,
VOLTage3,<n>,
CURRent:LIMit,<n>,
CURRent:PROTect:LEVel,<n>
CURRent:PROTect:TOUT,<n>
PHASe2,<n>,
PHASe3,<n>,
WAVEFORM,<n>, see Convention #11.
WAVEFORM1,<n>,
WAVEFORM2,<n>,
WAVEFORM3,<n>,
EVENTS,<n>,
AUTORMS,<n>
NSEGS,<n>
TRANSIENT SEGMENT PARAMETERS (OPTIONAL)
SEGment,<n>, Multiple segments per Program Message may be sent, see Convention 18
FSEG,<n>,
VSEG,<n>, see Convention #11.
VSEG1,<n>,
VSEG2,<n>,
VSEG3,<n>,
WFSEG,<n> see Convention #11.
WFSEG1,<n>,
WFSEG2,<n>,
WFSEG3,<n>,
TSEG,<n>,
LAST Sent only if this is the LAST segment.