Limited Warranty

How To... Front Panel Reference

Remote Interface Function Reference

Section 1: General Information

Using This Manual

Guides the user on how to navigate the manual and references key sections for operation.

Safety Notices and Precautions

Provides critical warnings and cautions regarding hazardous situations and equipment safety.

General Product Description

UPC Controller Description

Details the UPC controller's function as a signal generator, program storage, and interface compatibility.

UPC Controller Models

Explains the UPC-32 and UPC-12 models, highlighting their differences in output signals.

System Control Unit (SCU) Description

Describes the System Control Unit (SCU) chassis used to house the UPC controller.

Section 2: Specifications

Control Specifications Overview

Details control features like Transition Time, frequency, and voltage control specifications.

Frequency Control Specifications

Lists the frequency range, resolution, and accuracy of the UPC output.

Voltage Control Specifications

Describes voltage control modes, ranges, and transformer coupling options.

CSC (Continuous Self Calibration) Specifications

Explains the CSC function, its properties, and operational parameters.

Current Limit Control Specifications

Specifies the range, resolution, and accuracy for current limit control.

Current Protection Control Specifications

Details the current protection feature, threshold levels, and delay time.

Waveform Control Specifications

Covers waveform storage, editing, and generation capabilities.

Output Power Form Control Specifications

Explains how the UPC-32 and UPC-12 generate single, split, or three-phase outputs.

Phase Angle Control Specifications

Details the range, resolution, and accuracy for phase angle control.

Waveform Synthesis Specifications

Describes the optional Harmonic Analysis and Synthesis feature for waveform creation.

Metering Specifications Overview

Outlines the specifications for all metering functions of the UPC.

Voltmeter Specifications

Lists voltmeter ranges, resolution, and accuracy for line-to-neutral and line-to-line measurements.

Ammeter Specifications

Details ammeter ranges, resolution, accuracy, and crest factor measurement.

kVA Meter Specifications

Specifies the range and accuracy for kVA metering.

Kilowatt Meter Specifications

Specifies the range and accuracy for kilowatt metering.

Power Factor Meter Specifications

Specifies the range and accuracy for power factor metering.

Frequency Display Specifications

Details the programmed frequency display range, resolution, and accuracy.

Waveform Analysis (Optional)

Explains the optional waveform analysis for harmonic content and phase angle.

Electrical Interface Overview

Describes the electrical connections and interfaces of the UPC controller.

Isolation Characteristics

Explains the isolation characteristics of the UPC and remote interface.

Input Power Requirements

Details the input power requirements for the UPC and SCU.

Analog Outputs

Describes the analog outputs for oscillator waveforms.

Output Control Signals

Lists the digital outputs for controlling the power source.

Output Confirmation Signals

Lists the digital inputs for confirmation signals from the power source.

Analog Inputs

Describes the auxiliary and AM inputs for waveform generation and amplitude modulation.

Digital Outputs

Lists the digital outputs for transient triggers and synchronization signals.

Metering Inputs

Details the metering inputs for voltage and current measurements.

GPIB Remote Interface

Section 3: Installation Procedures

Remove Input Service

Instructions for disconnecting power and input service before installation.

Remove Cover and Cabling

Steps for removing the unit's cover and disconnecting internal cabling.

Remove Existing Controller

Procedures for removing any previously installed controller.

Configure UPC Settings

Details configuration settings for transformer ratio and Amps-to-Volts ratio.

Configure Transformer Ratio

Explains how to set the transformer ratio using DIP switches for correct operation.

Configure Amps to Volts Ratio

Details setting the Amps-to-Volts ratio via DIP switches for ammeter scaling.

Configure GPIB Device Address

Instructions for setting the GPIB device address for remote communication.

Configure Miscellaneous Settings

Explains various DIP switch settings for interface and hardware configuration.

Install UPC Unit

Steps for physically installing the UPC into the SCU front panel.

Install Cabling and Cover

Instructions for connecting internal cabling and reattaching the unit cover.

Connect Input Service

Steps for connecting input power and verifying voltage settings.

Section 4: Front Panel Operation

Guide to Operation

Introduces operational guidance, including overview and basic operation.

Overview of UPC Operation

Provides context for using the UPC controller locally or remotely.

Basic Operation Guide

Provides a quick method for setting voltage, frequency, and applying power using Manual Mode.

Front Panel Controls and Indicators

Identifies and defines functions of front panel controls and indicators.

Power Source Front Panel Controls

Explains controls and indicators on the power source front panel relevant to UPC operation.

UPC Front Panel Controls

Defines the function of each key and LED on the UPC front panel.

Manual Mode Operation

Describes how to operate the UPC using Manual Mode for voltage and frequency control.

Metering Displays

Explains the V/I METER display and how to cycle through metering displays.

Waveform Analysis (Optional)

Explains the optional waveform analysis for harmonic content and phase angle.

Voltage Entry in Manual Mode

Instructions for entering voltage values and using slew controls in Manual Mode.

Frequency Control in Manual Mode

Instructions for entering frequency values and using slew controls in Manual Mode.

Program Operate Mode

Describes how to execute pre-stored programs and transients.

Program Execution

Steps for selecting and executing a stored program.

Transient Execution

How to create and execute transient events within stored programs.

MIL-STD-704 D Transient Programs

Details pre-stored programs for MIL-STD-704D over-voltage and under-voltage transients.

Program Edit Mode

Covers how to create and edit programs and transients.

Program Editing Process

Steps for editing steady-state parameters of a program.

Program Example: Creating and Executing

Provides an example of creating and executing a 3-phase program.

Transient Editing Process

Explains how to create and edit transient events for programs.

Time Based Transient Example

Provides an example of creating a time-based transient event.

Cycle Based Transient Example

Provides an example of creating a cycle-based transient event.

Setup Mode Access

Explains how to access and use the SETUP MENU for system configuration.

Program Setup Options

Details how to copy, delete programs, and initialize settings.

Initialize Programs, Waveforms, Setup

How to reset all programs, waveforms, and setup to factory defaults.

Erase All RAM and Reset CPU

Procedure for a full system reset by clearing RAM and resetting the CPU.

Waveform Setup and Management

Explains how to copy, edit, and synthesize waveforms.

Edit Waveform Parameters

Instructions for editing existing waveforms, including phase angle and voltage.

Copy Waveform Functionality

How to copy waveforms from one number to another with scale factor adjustment.

Waveform Synthesis Functionality

Explains creating waveforms using harmonic analysis and synthesis.

General Setup Configuration

Covers system configuration settings like setup menus and options.

UPC Setup Configuration

Configures sense points, CSC, output impedance, and transition time.

Programmable Output Impedance Setup

Details the setup and caution for the Programmable Output Impedance option.

Programmable Output Impedance Calibration

Explains calibration procedures for programmable output impedance.

Liquid Crystal Display Setup

How to adjust LCD view angle and backlight intensity.

UPC Status Information

Displays firmware version, interface status, and configuration settings.

Power Source Status Diagnostics

Shows internal control signals between UPC and power source for diagnostics.

Range Control Settings

Explains how the UPC displays Range Control parameters.

Slew Rate Setup

How to set slew rates for arrow key transitions.

Initial Voltage Configuration

How to set the initial power-up output voltage.

Keyboard Lock Functionality

How to enable or disable the keyboard lock feature.

Current Protect Feature

How to enable and disable the current protection feature.

Section 5: GPIB and Remote Operation

Introduction to Remote Control

Introduces remote control, REN line, and LOCAL/REMOTE control switching.

Command and Syntax Conventions

Explains command syntax, SCPI standards, and formatting conventions.

Program Control Commands

Covers commands for managing programs, including execution, definition, and copying.

Steady-State Output Parameters

Lists parameters for defining steady-state output conditions in programs.

Transient Segment Parameters

Details parameters for defining transient segments, including Time, Voltage, and Waveform.

Program Memory Control Commands

Commands for deleting programs and managing program memory.

Signal Control Commands

Commands for controlling output signals like voltage, frequency, and waveform.

Output Parameter Commands

Lists commands for setting output voltage, frequency, current limit, and phase angle.

Signal Routing Commands

Commands for setting output form, coupling, sense path, and spectrum range.

Waveform Control Commands

Commands for loading, querying, and defining waveforms remotely.

Query Functions Overview

Functions for querying UPC status and configuration parameters.

Configuration Queries

Queries for transformer ratio, AMPs:VOLTS ratio, CT location, amplifiers, and current range.

Metered Data Queries

Commands to query metered voltage, current, frequency, power, and power factor values.

Event and Status Reporting

Covers querying events and status registers for system monitoring.

IEEE-488.2 Status Reporting

Details status reporting commands like *STB?, *ESR?, and system error queries.

SCPI Status Reporting

Details SCPI status registers for Operation and Questionable conditions.

Device Control Commands Overview

Commands for controlling device functions like beeper, keyboard lock, and calibration.

IEEE-488.1 Interface Functions

Lists IEEE-488.1 interface functions supported by the UPC.

IEEE-488.2 Device Control Commands

Lists IEEE-488.2 common commands for device control, including *RST and *LLO.

Remote Control Examples

Provides examples of common remote control operations.

Example: Storing a Program

Demonstrates how to store a program remotely using SCPI commands.

Example: Querying a Program

Shows how to query a stored program's parameters remotely.

Example: Executing a Stored Program

Demonstrates remotely executing a stored program.

Example: Executing a Stored Program Transient

Shows how to remotely execute a stored program's transient event.

Example: Changing Output Parameters

Demonstrates remotely changing output parameters like frequency and voltage.

Example: Voltage and Current Measurement Query

Demonstrates querying phase RMS voltages and currents remotely.

Example: Voltage and Current Waveform Query

Shows how to remotely query waveform data for voltage and current.

Section 6: Maintenance

Section 7: Service Information

Section 8: Calibration Procedures

Calibration Interval Recommendations

Recommends calibration frequency for accurate control and measurement.

Test Equipment Requirements

Lists the necessary test equipment for calibration procedures.

Manual Calibration Procedure

Outlines the manual calibration steps for system gains and parameters.

Oscillator Gain Calibration

Steps for calibrating the oscillator gains for accurate voltage output.

Programmable Current Limit Calibration

Procedure for calibrating the programmable current limit.

Output Voltmeter Calibration

Steps for calibrating the output voltmeter for accurate metering.

Externally Referenced Calibration

Explains how to calibrate UPC metering using external references.

kFactor Display and Calculation

How to view and manually calculate kFactors for metering calibration.

Reset All kFactors

How to reset all kFactors to factory defaults.

Section 9: User Diagnostics and Troubleshooting

Troubleshooting Common Problems

Helps users solve common problems and errors encountered with the UPC.

Problem: Incorrect Operation or Error Messages

Addresses issues like incorrect operation, invalid values, or specific error messages.

Problem: LCD Display Issues

Addresses issues with an unreadable LCD display.

Problem: Voltage Range Errors

Addresses errors related to programmed output voltage exceeding range.

Problem: Keys Beep, Display Unresponsive

Addresses keys beeping but the display not responding.

Problem: Keys Do Not Respond

Addresses a problem where keys do not respond at all.

Problem: No GPIB Response

Addresses issues with the UPC not responding to GPIB commands.

Problem: No Serial Port Response

Addresses UPC not responding to serial port commands or showing command errors.

Section 10: Serial Remote Interface Option

General Serial Interface Information

Introduces the Serial Remote Interface as an alternative to GPIB.

Serial Port Communication Specifications

Details baud rates, parity, EOS, data bits, and handshake characteristics.

Serial Interface Installation

Describes the physical installation of the Serial Interface.

Serial Interface Setup

Covers setting serial communication parameters like Baud Rate, Parity, and EOS.

Serial Remote Interface Operation

Explains how to operate the UPC via the Serial Remote Interface.

Communication Monitoring Aid

Describes the UPC STATUS display for monitoring serial communication.

Functional Exceptions for Serial Interface

Lists IEEE-488 interface functions not applicable to the Serial Interface.

Functional Additions for Serial Interface

Lists added commands for Serial Interface, similar to IEEE-488.2.

Testing the Serial Remote Interface

Provides steps for testing the serial communication interface.

Physical Connections for Serial Interface

Details the pinouts for the UPC Serial Interface DB-25 and PC DB-9 connectors.

Notes

Modifications

Pacific Power Source UPC-32 Specifications

General IconGeneral
BrandPacific Power Source
ModelUPC-32
CategoryController
LanguageEnglish

Related product manuals