SECTION 5 REMOTE OPERATION
79
5.5.2 METERED DATA QUERIES (continued)
:MEASure:CURRent:CREST1?
Query: metered current Crest Factor ФA
Returns <0> to <1000>
:MEASure:CURRent:CREST2?
Query: metered current Crest Factor ФB
Returns <0> to <1000>
:MEASure:CURRent:CREST3?
Query: metered current Crest Factor ФC
Returns <0> to <1000>
:MEASure:POWer1?
Query: metered Kilowatts ФA
Returns <0> to <1000> KW
:MEASure:POWer2?
Query: metered Kilowatts ФB
Returns <0> to <1000> KW
:MEASure:POWer3?
Query: metered Kilowatts ФC
Returns <0> to <1000> KW
:MEASure:KVA1?
Query: metered KiloVoltAmps ФA
Returns <0> to <1000> KVA
:MEASure:KVA2?
Query: metered KiloVoltAmps ФB
Returns <0> to <1000> KVA
:MEASure:KVA3?
Query: metered KiloVoltAmps ФC
Returns <0> to <1000> KVA
:MEASure:PF1?
Query: metered power factor (KW/KVA) ФA
Returns <0> to <1.0>
:MEASure:PF2?
Query: metered power factor (KW/KVA) ФB
Returns <0> to <1.0>
:MEASure:PF3?
Query: metered power factor (KW/KVA) ФC
Returns <0> to <1.0>
:FETCh[:WAVEform]:VOLT1?
:FETCh[:WAVEform]:CURRent1?
Query: metered waveform data (line-to-neutral voltage
only)
:VOLT1 for ФA, :VOLT2 for ФB, and :VOLT3 for ФC volts
:CURR1 for ФA, :CURR2 for ФB, and :CURR3 for ФC
current
Returns a string of 512, NR2 type numbers, comma
delimited. Each waveform string is terminated by a semi-
colon. Only a single waveform may be queried in a
command.