SECTION 5 REMOTE OPERATION
73
5.3.2 TRANSIENT SEGMENT PARAMETERS (continued)
sets execution time (to reach objective Voltage and Frequency) of
selected segment
n = <0> or <.0002> to <300> seconds. Setting n to <0> selects
cycle-based transient operation, i.e., each segment time is equal to
the period of 1 cycle (1/FREQ)
sets selected segment to be the last segment of selected transient
5.3.3 PROGRAM MEMORY CONTROL
:PROGram:[SELected:]DELete
Command: (No query) deletes selected program.
Attempting to DELete an EXECuting Program will report an Error.
Command: (No query) deletes all programs, waveforms, calibration
data, and setup values, performs device RESET, loads Program #1
with *RST default values (5.6.2), executes MANUAL MODE with
*RST values. Waveforms (1-16) are re-loaded from ROM
Attempting to DELete an EXECuting Program will report an Error
NOTE: Calibration values are deleted
Command: (No query) copies the selected program (previously
specified by :PROG:NAME <nn>) to <dest>
<dest> = 1 thru 99
NOTE: that the destination Program cannot be currently EXECuting
Query: returns <list>, a comma separated list of NR1 values
representing stored programs (e.g. 1,2,7…). If the MANUAL MODE
program exists, list includes 0. If no programs are stored, query
returns -1
5.4 SIGNAL CONTROL
5.4.1 OUTPUT PARAMETERS
Command: executes selected Program steady-state values.
Selected program is specified by previous PROGram:NAME <nn>
command
Query: returns the number of the currently executing program. If no
program is executing, query returns -1
Command: (No query) executes pre-processed Transient portion of
selected Program. Pre-processing is performed by executing a
Program. Transient terminates upon receipt of any data byte (DAB)
from the IEEE-488 Bus, Device Clear, or when the LAST segment of
the last EVENT is executed. Steady-state values are then restored.
Follow this command (in the same Program Message) with *OPC
(5.5.3.1) to detect termination of the Transient event. An SRQ
occurs when the Transient is complete (if ESB bit is set in SRE and
OPC bit is set in ESE). *OPC? may be used in the same manner