EasyManua.ls Logo

Panasonic CS-Z25UB4EAW

Panasonic CS-Z25UB4EAW
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
3. Specifications
Model
Indoor CS-Z25UB4EAW CS-Z35UB4EAW
Outdoor CU-Z25UBEA CU-Z35UBEA
Performance Test Condition EUROVENT EUROVENT
Power Supply
Phase, Hz Single, 50 Single, 50
V 230 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.85 2.50 3.20 0.85 3.50 4.00
BTU/h 2900 8530 10900 2900 11900 13600
Kcal/h 730 2150 2750 730 3010 3440
Running Current A – 2.50 – – 4.10 –
Input Power W 240 550 820 240 900 1.18k
Annual Consumption kWh – 275 – – 450 –
EER
W/W 3.54 4.55 3.90 3.54 3.89 3.39
BTU/hW 12.08 15.51 13.29 12.08 13.22 11.53
Kcal/hW 3.04 3.91 3.35 3.04 3.34 2.92
ErP
Pdesign kW 2.5 3.5
SEER (W/W) 6.3 6.5
Annual
Consumption
kWh 139 188
Class A++ A++
Power Factor % – 96 – – 95 –
Indoor Noise (H / L / QLo)
dB-A 34 / 25 / 22 34 / 26 / 23
Power Level dB 50 / – 50 / –
Outdoor Noise (H / L)
dB-A 46 / – 48 / –
Power Level dB 61 / – 63 / –
Heating
Capacity
kW 0.85 3.20 4.80 0.85 4.50 5.60
BTU/h 2900 10900 16400 2900 15300 19100
Kcal/h 730 2750 4130 730 3870 4820
Running Current A – 3.60 – – 6.00 –
Input Power W 230 790 1.32k 230 1.36k 1.75k
COP
W/W 3.70 4.05 3.64 3.70 3.31 3.20
BTU/hW 12.61 13.80 12.42 12.61 11.25 10.91
Kcal/hW 3.17 3.48 3.13 3.17 2.85 2.75
ErP
Pdesign kW 2.7 3.0
Tbivalent °C -10 -10
SCOP (W/W) 4.3 4.2
Annual
Consumption
kWh 879 1000
Class A+ A+
Power Factor % – 95 – – 99 –
Indoor Noise (H / L / QLo)
dB-A 35 / 28 / 25 35 / 28 / 25
Power Level dB 51 / – 51 / –
Outdoor Noise (H / L)
dB-A 47 / – 48 / –
Power Level dB 62 / – 63 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 3.48 / 1.17k / 2.97 4.06 / 1.55k / 2.62
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 2.88 / 1.19k / 2.42 3.37 / 1.60k / 2.11
Max Current (A) / Max Input Power (W) 6.2 / 1.32k 8.0 / 1.75k
Starting Current (A) 3.60 6.00

Table of Contents