21.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 20°C Dry Bulb/ -°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 230V
21.2.1 CS-Z25UB4EAW CU-Z25UBEA
1.50
2.00
2.50
3.00
3.50
4.00
4.50
-20 -15 -10 -5 0 5 10 15
Current
(A)
Outdoor Air Temperature (°C)
1.4
1.6
1.8
2.0
2.2
2.4
2.6
-20 -15 -10 -5 0 5 10 15
Hi Pressure (MPa)
Outdoor Air Temperature (°C)
20
24
28
32
36
40
-20 -15 -10 -5 0 5 10 15
Indoor Discharge
Air Temperature
(°C)
Outdoor Air Temperature (°C)