17.2.2 Operation mode during Heating Only Operation
The table below shows the operation mode comparison when Heating Only Operation Mode Activated and
Deactivated.
Operation
Mode
Heating Only Operation Mode Activated Heating Only Operation Mode Deactivated
AUTO
After 30s sampling, regardless of the indoor intake or
outdoor intake temperature judgment, the unit will run
Heating operation.
After 30s sampling, the unit will judge the operation
mode base on remote controller temperature setting and
Indoor Intake Sensor (New Auto Mode) or Outdoor
Intake Sensor (Old Auto Mode).
HEAT The unit will run Heating operation. The unit will run Heating operation.
COOL The unit will stop and Power LED blinking. The unit will run Cooling operation.
DRY The unit will stop and Power LED blinking. The unit will run Cooling Dry operation.
NANOE
Stand-alone
The unit will stop and Power LED blinking. The unit will run Nanoe Stand-alone operation.
Force Cooling
The unit will run Force Cooling Operation for
X_CTRYTM [15] minutes
The unit will run Force Cooling operation.
Force Heating The unit will run Force Heating operation. The unit will run Force Heating operation.
AUTO
(with Timer)
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, regardless of the indoor
intake or outdoor intake temperature judgment, the unit
will run Heating operation.
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, the unit will judge the
operation mode base on remote controller temperature
setting and Indoor Intake Sensor (New Auto Mode) or
Outdoor Intake Sensor (Old Auto Mode).
HEAT
(with Timer)
The unit will turn ON by the timer and run Heating
Operation.
The unit will turn ON by the timer and run Heating
Operation.
COOL
(with Timer)
The unit will not turn ON by the timer. Power LED
blinking.
The unit will turn ON by the timer and run Cooling
Operation.
DRY
(with Timer)
The unit will not turn ON by the timer. Power LED
blinking.
The unit will turn ON by the timer and run Cooling Dry
Operation.
Cooling
Test Mode
The unit will stop and Power LED blinking.
The unit will operate according to specify Cooling test
mode operation parameter.
Heating
Test Mode
The unit will operate according to specify Heating test
mode operation parameter.
The unit will operate according to specify Heating test
mode operation parameter.

Table of Contents

Other manuals for Panasonic CS-Z25VKEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-Z25VKEW and is the answer not in the manual?

Panasonic CS-Z25VKEW Specifications

General IconGeneral
AC input voltage230 V
Design load (cooling)2.5 kW
Annual energy consumption (cooling)103 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.7 kW
Energy efficiency class (heating) (Colder heating season)-
Energy efficiency class (heating) (Average heating season)A+++
Annual energy consumption (heating) (Average heating season)741 kWh
TypeAir conditioner indoor unit
Multi-splitNo
Product colorWhite
Dehumidifying capacity1.5 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3200 W
Cooling capacity in watts (min)850 W
Heating capacity in watts (max)5000 W
Heating capacity in watts (min)800 W
Cooling capacity in watts (nominal)2500 W
Cooling energy efficiency (EER, W/W)4.81
Heating energy efficiency (COP, W/W)4.79
Seasonal efficiency rating (cooling) (SEER)8.5
Seasonal efficiency rating (heating) (SCOP)5.1
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3400 W
Indoor unit typeWall-mountable
Indoor unit depth194 mm
Indoor unit width919 mm
Indoor unit height295 mm
Indoor unit weight10000 g
Indoor units quantity1
Cooling airflow (indoor unit)612 m³/h
Heating airflow (indoor unit)672 m³/h
Indoor unit sound power level55 dB
Indoor unit noise level (low speed)19 dB
Indoor unit noise level (high speed)39 dB
Wi-FiYes
Outdoor unit noise level- dB