13.7 Repairing of refrigerant cycle / Brazing point
13.7.1 Preparation for repairing of refrigerant cycle / brazing
Brazing which is a technique needed for repairing refrigerant cycle requires advanced technique and experience, and
this brazing procedure can only be performed by the workers who completed “Gas Welding Skill Training” regulated
by the Occupational Safety and Health Act, and went through the training programs of refrigerant operations.
Dismantling and re-connecting (assembling) refrigerant system requires working space, and the space has to ensure
good air flow and fire prevention (water bucket and fire extinguisher). Moreover, the worker has to ensure the
wearing of goggles, grabs, safety shoes, and long sleeve shirts, and be aware of work safety and attempt to prevent
secondary defect (quality assurance of products). For brazing the indoor / outdoor unit structural components (heat
exchangers, compressors, expansion valves, four-way valve blocks), after the recovery of all refrigerant, confirm that
no refrigerant remains in the system, and fully open the 2-way and 3-way valves. When the brazing is conducted
outside, check and make sure no refrigerant is contained in the air (be careful with vaporized refrigerant).
Furthermore, protect the compressor terminal with metal plates, and heat but use wet clothes to cool down (releasing
the heat) the expansion valves, and four way valves (prevent destruction of parts). In brazing, it is important to pour
the brazing material without melting the base metal based on capillary action principle. In case of holes and oxidizing
caused by overheating, do not perform re-brazing or alteration but replace the parts.
13.7.2 Adjustment of vacuum pump pressure
1. Cylinder with adjustment handle
1. Check and confirm the adjustment handle of the 1
st
pressure adjuster is loosen (anticlockwise). If cylinder
valve is opened when the 1
st
gauge pressure adjust handle is closed, the 2
nd
gauge might get broken.
The primary gauge
(High pressure)
The secondary gauge
(Low pressure)
The secondary gauge
(Low pressure)
Adjustment
handle
Adjustment
handle
Oxygen regulator
Propane regulator
Main valve
Main valve
2. Open the cylinder valve, and check the remaining amount with the first t side pressure gauge.
3. Check the pressure of 2
nd
gauge and turn the adjustment handle to clock-wise direction to adjust the
pressure.
Oxygen 2
nd
side gauge pressure・・・・・・・・・・0.5 MPa (5.0 kgf / cm
2
)
Propane 2
nd
side gauge pressure・・・・・・0.05 MPa (0.5 kgf / cm
2
)

Table of Contents

Other manuals for Panasonic CS-Z25VKEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-Z25VKEW and is the answer not in the manual?

Panasonic CS-Z25VKEW Specifications

General IconGeneral
AC input voltage230 V
Design load (cooling)2.5 kW
Annual energy consumption (cooling)103 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.7 kW
Energy efficiency class (heating) (Colder heating season)-
Energy efficiency class (heating) (Average heating season)A+++
Annual energy consumption (heating) (Average heating season)741 kWh
TypeAir conditioner indoor unit
Multi-splitNo
Product colorWhite
Dehumidifying capacity1.5 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3200 W
Cooling capacity in watts (min)850 W
Heating capacity in watts (max)5000 W
Heating capacity in watts (min)800 W
Cooling capacity in watts (nominal)2500 W
Cooling energy efficiency (EER, W/W)4.81
Heating energy efficiency (COP, W/W)4.79
Seasonal efficiency rating (cooling) (SEER)8.5
Seasonal efficiency rating (heating) (SCOP)5.1
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3400 W
Indoor unit typeWall-mountable
Indoor unit depth194 mm
Indoor unit width919 mm
Indoor unit height295 mm
Indoor unit weight10000 g
Indoor units quantity1
Cooling airflow (indoor unit)612 m³/h
Heating airflow (indoor unit)672 m³/h
Indoor unit sound power level55 dB
Indoor unit noise level (low speed)19 dB
Indoor unit noise level (high speed)39 dB