EYFR03 User Manual 53 of 110 v1.6.0
Chapter 4: 20 January 2020
Values: Variable, Fixed (1-25 characters)
This setting determines how long a scan must be to be considered a valid VIN. When set to
Variable, any scan length up to 25 characters is allowed. When running in None mode, this
setting allows you to specify the length of a VIN scan without using the rest of the VIN
Selections features.
Selector length
Default: Variable
Values: Variable, Fixed (1-25 characters)
This setting determines how long a scan must be to be considered a valid selector. When set to
Variable, any scan length up to 25 characters is allowed. When running in None or Single Scan
modes, this setting is ignored.
Characters to match
This setting is used to specify which characters in a scan the EYFR03 should look at when
comparing against the selection list. You may select some or all the characters and are allowed
to have gaps between matched characters if needed.
VIN Selection Matches
Each entry in the VIN Selection Match list has a few values that you can set.
Match – The string of characters that must be found in the scan.
Type – The type of item to be selected for a matching selector. One of Parameter, Group, or Job.
Number – The item number to be selected for a matching selector. 1-100.
Batch – If selecting a batch, the batch size to use for a matching selector. 0 to use the batch size
defined in the parameter, or 1-255 to override the batch size defined in the parameter.
Match Examples
Consider the following selectors:
1FV6HLBAXP
1FVPP3BX5M
JH2RC441X2
To have the EYFR03 look at the marked (bold/underline) characters in the scans for its match,
you would select characters 2, 3, and 7 as the Characters to match. To match the first two scans,
you would enter “FVB” for the Match field in the selection list. To match the third scan, you
would enter “H24” for the Match field in the selection list.