EasyManua.ls Logo

Panasonic EYFR03 - Page 77

Panasonic EYFR03
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EYFR03 User Manual 77 of 110 v1.6.0
Chapter 7: EtherNet/IPTM 20 January 2020
C.E. Parameter Object
Class Code: 65 Hex
The C.E. Parameter Object refers to a parameter that describes the required operation for a batch
of tightenings. This should not be confused with the Parameter Object (class code 10 hex)
defined in the open portion of the Ethernet/IP
TM
protocol, which has a different use and is not
implemented in this product line.
Class Attributes
ID
Access
Name
Data Type
Description of Attribute
Semantics of Value
1
Get
Revision
UINT
Revision of this object
1
2
Get
Max Instance
UINT
Maximum instance number
of a parameter set object in
the device.
The maximum number of
parameters as specified
for the product.
Instance Attributes
ID
Access
Name
Data Type
Description of Attribute
Semantics of Value
1
Set
Name
SHORT_STRING
Name of the parameter
displayed on screen and
reported in results
Maximum length is 25
characters
2
Get
Last Modified
DT
Last time the parameter
attributes were modified
3
Set
Tools
UINT
Instance numbers of tool
used for this parameter
5
Set
Batch
USINT
Batch size
6
Get
Number of
Batches
UINT
Number of batches run in
this parameter
This value resets on
powerup.
Services
Service
Code
Available in
Service Name
Description of Service
Class
Instance
0x05
No
Yes
Reset
Resets the parameter to factory defaults.
0x0E
Yes
Yes
Get_Attribute_Single
Returns the contents of the specified attribute.
0x10
No
Yes
Set_Attribute_Single
Modifies a single attribute.

Table of Contents