101
KX-FP365CX / KX-FM388CX
OK means “can set”.
NG means “can not set”.
Note:
*1
Power is OFF/ON after changing this set value.
Refer to Service Function Table (P.67) for descriptions of the individual codes.
Example:
If you want to set value in the “004 Sending report”, press the dial key number 1,2 or 3 corresponding to the Set Value you want
to select. (1:ERROR / 2:ON / 3:OFF)
567 T0 timer 001 ~ 255 sec 046 sec OK
570 Break % select 1: 61% / 2: 67% 61% OK
571 ITS auto redial time set 00 ~ 99 05 OK
572 ITS auto redial line disconnection time set 001 ~ 999 sec 185 sec OK
573 Remote turn-on ring number set 00 ~ 99 10 OK
580 TAM continuous tone detection 1: ON / 2: OFF ON OK
590 FAX auto redial time set 00 ~ 99 05 OK
591 FAX auto redial line disconnection time set 001 ~ 999 sec 185 sec OK
592 CNG transmit select 1: OFF / 2: ALL / 3: AUTO ALL OK
593 Time between CED and 300 bps 1: 75 msec / 2: 500 msec / 3: 1 sec 75 msec OK
594 Overseas DIS detection select 1: 1st / 2: 2nd 1st OK
595 Receive error limit value set 1: 5% / 2: 10% / 3: 15% / 4: 20% 10% OK
596 Transmit level set 00 ~ 15 × -1 dBm 11 × -1 dBm OK
598
*1
Receiving Sensitivity 20 ~ 48 × -1 dBm 42 × -1 dBm OK
599 ECM Frame size 1:256 byte / 2: 64 byte 256 byte OK
624 AT ring time out (KX-FM388 only) 1: 3 sec / 2: 5 sec 3 sec OK
625 Setting printing density 1: Default / 2: Lighter / 3: Darker Default OK
710 Memory clear except History data --------- --------- NG
717 Transmit speed select 1: 14400 / 2: 12000 / 3: 9600 / 4: 7200 /
5: 4800 / 6: 2400 bps
14400 bps OK
718 Receive speed select 1: 14400 / 2: 12000 / 3: 9600 / 4: 7200 /
5: 4800 / 6: 2400 bps
14400 bps OK
722 Redial tone detect 1: ON / 2: OFF ON OK
724 PC-SEND busy tone detection (KX-FM388 only) 1: ON / 2: OFF OFF OK
745 Power on film feed 1: ON / 2: OFF ON OK
763 CNG detect time for friendly reception 1: 10 sec / 2: 20 sec / 3: 30 sec 30 sec OK
773 DIS-DCS interval 1: 500 msec / 2: 200 msec 200 ms OK
774 T4 timer 00~99 × 100 msec 00 × 100 ms OK
784 Voice Prompt Test --------- --------- NG
815 Sensor test & Vox test --------- --------- NG
841 Digital SP-Phone RX & TX check --------- --------- NG
845 Setting scanning density 00 ~ 32 08 OK
852 Print test pattern --------- --------- NG
853 Top margin 1 ~ 9 mm 5 mm OK
861 Paper size 1: A4 / 2: LETTER A4 OK
874 DTMF ON time 06 ~ 20 × 10msec 10 × 10 msec OK
875 DTMF OFF time 06 ~ 20 × 10msec 10 × 10 msec OK
880 History list --------- --------- NG
881 Journal 2 --------- --------- NG
882 Journal 3 --------- --------- NG
961 The time transmitting the false ring back tone 01~10 sec 07 sec OK
962 The operator calling time 05~30 sec 10 sec OK
991 Setup list 1: Start --------- OK
994 Journal list 1: Start --------- OK
995 Journal 2 list 1: Start --------- OK
996 Journal 3 list 1: Start --------- OK
998 History list 1: Start --------- OK
999 Service list 1: Start --------- OK
Code Function Set Value Default Remote Set-
ting

Table of Contents