KX-FP365CX / KX-FM388CX
11.1.4. Memory Clear Specification
*
1
Execute Service Mode #550 when you want to reset the all setting data keeping the user information.
*
2
Execute Service Mode #710 to clear the user information in case that Main Unit is recycled.
Note:
• Please restart a power supply after clearing a memory.
784 Voice Prompt Test See Test Mode (P.63).
815 Sensor test & Vox test See Test Mode (P.63).
841 Digital SP-Phone check See Digital Speakerphone (P.127).
845 Setting scanning density 00~32 00~32 08 Select scanning density when the code No.58 is set
“Normal”. If you want darker, select smaller value. If you
want fainter, select larger value. Refer to Program
Mode Table (P.100).
852 Print test pattern See Test Mode (P.63).
853 Top margin × mm 1~9 5 ----------
861 Paper size 1: A4
2: LETTER
1, 2 1 ----------
874 DTMF ON time × 10 msec 06~20 10 ----------
875 DTMF OFF time × 10 msec 06~20 10 ----------
880 History list ----------
881 Journal 2 list See Special Service Journal Report (P.86).
882 Journal 3 list See Special Service Journal Report (P.86).
961 The time transmitting the false ring back
tone
× sec 01~10 07 Set the time transmitting the false ring back tone to the
line in TEL/FAX mode.
962 The operator calling time × sec 05~30 10 Set the operator calling time through the speaker in
TEL/FAX mode.
Code Function Set Value Effective
Range