EasyManua.ls Logo

Panasonic KX-FP365CX

Panasonic KX-FP365CX
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
129
KX-FP365CX / KX-FM388CX
12.5.8. Power Supply Board Section
12.5.8.1. Key Components for Troubleshooting
Check the following parts first: F101, D101-D104, C106, Q101and IC101.
This comes from our experience with experimental tests. For example: power supply and lightning surge voltage test, withstanding
voltage test, intentional short circuit test, etc.
Caution:
If you find a melted fuse in the unit, do not turn on the power until you locate and repair the faulty parts (except for the fuse);
otherwise the fuse will melt again and you cannot pinpoint the faulty point.
In most cases, the symptom is that nothing is output. It is more likely that the fault is in the primary side rather than the secondary
side. Check the primary side first.