Programming Manual References
None
Feature Manual References
13.1.4 Pause Insertion
8.1.5 Host PBX Access Code (Access Code to the Telephone Company from a Host PBX)
16.1.5 Special Carrier Access Code
Flash Time
Specifies the length of a flash signal.
Default
608 ms
Value Range
None, 16 ´ n (n=1–255) ms
Maintenance Console Location
3.34 [1-1] Slot—Port Property - T1 Port
Programming Manual References
None
Feature Manual References
5.1.1 EFA (External Feature Access)
Disconnect Time
Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize the line.
Default
1.5 s
Value Range
0.5 s, 1.5 s, 2.0 s, 4.0 s, 12.0 s
Maintenance Console Location
3.34 [1-1] Slot—Port Property - T1 Port
Programming Manual References
None
Feature Manual References
6.1.2 Flash/Recall/Terminate
294 PC Programming Manual Document Version 2009-12
3.34 [1-1] Slot—Port Property - T1 Port