- App. 32 -
Details of Parameters
PrNo. Parameter
Value
Function
For linear motion or other similar motion, overtraveling of the work may cause mechanical
damages. To avoid this, it is necessary to provide a limit switches at each end so that traveling
over the limit switch position can be inhibited.
<Notes>
1. With Pr04 = 0 and CCW/CW off (not connected to COM-), the
driver will trip with "overtravel limit input error" assuming that
traveling over the limit occurs simultaneously in both the CCW
and CW directions.
2.
You can specify whether or not to use the dynamic brake
during deceleration after CCW or CW overtravel limit
input (CCWL or CWL) becomes active. For details, see
the description of Pr66 (DB inhibition at overtravel limit).
04
Overtravel
input inhibit
0 ~ 1
[1]
CW direction CCW direction
CCWL
CWL
Work
Servo
motor
Limit
switch
Limit
switch
Driver
Value
0
1
CCWL/CWL
input
Enabled
Disabled
Input
CCWL
ÅiCN I/F-9Åj
CWL
ÅiCN I/F-8Åj
Operation
Normal with the CCW limit
switch not activated
Å@
Normal with the CW limit
switch not activated
Å@
Connection to COM-
Disabled
Open (H)
Connection
(L)
Open (H)
Both the CCWL and CWL inputs are disabled, and traveling
in both the CW and CCW directions are allowed.
Traveling in CCW direction limited, CW
direction allowed
Traveling in CW direction limited, CCW
direction allowed