No.SX-DSV01676 - 43 -
R2 Motor Company, Matsushita Electric Industrial Co., Ltd.
12-2-4 Noise filter
When you install one noise filter at the power supply in multi-axes application, consult with the manufacture
of the filter.
Option part No. Voltage for drive Manufacturer’s part No. Applied to Manufacturer
DV0P4170 Single phase 100V 200V SUP-EK5-ER-6 type A and B
DV0P4180 3SUP-HQ10-ER-6 type C
DV0P4220 3SUP-HU30-ER-6 type D and E
DV0P3410
3-phase 200V
3SUP-HL50-ER-6 type F
Okaya Electric
Industries Co., Ltd.
12-2-5 Surge absorber
Install a surge absorber at primary side of a noise filter.
(Remarks)
Take off the surge absorber when you execute dielectric test to the machine, or it may damage the surge
absorber.
Option part No. Voltage for drive Manufacturer’s part No. Manufacturer
DV0P1450 3-phase 200V R·A·V-781BXZ-4
DV0P4190 Single phase 100V 200V R·A·V-781BWZ-4
Okaya Electric
Industries Co., Ltd.
12-2-6 Noise filter for signal line
Install noise filter for signal line to all cables (power line, motor cable, encoder cable and interface cable)
Install 3 filters to the power line.
Option part No. Manufacturer’s part No. Manufacturer
DV0P1460 ZCAT3035-1330 TDK
12-2-7 Earth
(1) Connect the protective earth terminal ( ) and protective earth of the control box (PE) without fail.
(2) Do not make a joint connection to the protective earth terminal ( ). 2 protective terminals are
provided.