B29
−−
B28
−
English
4. Parameter
Outline / Setup / Connection
Outline of Parameter
Thisdriverisequippedwithvariousparameterstosetupitscharacteristicsandfunc-
tions.Thissectiondescribesthefunctionandpurposeofeachparameter.Readand
comprehendverywellsothatyoucanadjustthisdriverinoptimumconditionforyour
runningrequirements.
• You can refer and set up the parameter with either one of the following.
1)frontpanelofthedriver
2)combinationofthesetupsupportsoftware,"PANATERM"andPC.
Setup with the Front Panel
Press these to change display and data,
select parameters and execute actions.
(Change/Selection/Execution is valid to the
digit which decimal point flashes.)
Numerical value increases by pressing, ,
decreases by pressing .
Shifting of the digit for data
changing to higher digit.
X7
Output connector for monitor
Display LED (6-digit)
Switch to error display screen when error
occurs, and LED will flash (about 2 Hz).
LED will flash slowly (about 1 Hz) when
warning occurs.
Mode switching button
(valid at SELECTION display)
Press this to switch 4 kinds of mode.
1) Monitor Mode
2) Parameter Set up Mode
3) EEPROM Write Mode
4) Auxiliary Function Mode
SET Button (valid at any time)
Press this to switch SELECTION and
EXECUTION display.
6 1
X7
3. System Conguration and Wiring
Wiring to the connector, X7
TheconnectorX7ofthefrontpanelisformonitoroutput.
Analogueoutput:2systems
Inbothcases,itispossibletoswitchtheoutputsignalbysettingparameters.
Application Symbol
Connector
Pin No.
Contents
Analoguemonitor
output1
AM1 1
• Outputtheanaloguesignalfor
monitor.
• Theamplitudeoftheoutputsignalis
±10V.
• Outputimpedanceis1kΩ.When
connectingameasuringinstrument,
checkitsinputcircuitforimpedance
matching.
Analoguemonitor
output2
AM2 2
Signalground GND 3 Connectedtogroundofcontrolcircuit.
NC – 4 Donotconnect.
NC – 5 Donotconnect.
NC – 6 Donotconnect.
Connector X7
Manufacturer’s part No.:
530140610
Manufacturer:
Japan Molex Inc.
6 1
X7
Measuring
instrument
Output circuit
1
1 kΩ
AM1
GND
3
1 kΩ
AM2
2
Remarks
X1toX7areusedforthesecondarycircuit.Toconnecttheseterminalstotheprimary
powersupply(particularly,the24VDCpowersupplyforbrake),insulationisrequired.
Donotconnecttheseterminalstothesamepowersupply.