B39
−−
B38
−
English
LABEL
Terminal cover
(transparent)
2–ø4.5
R
Cx Cx
Cy
L L
Cy
2–ø4.5 x 6.75
53.1±1.0
100.0±2.0
88.0
75.0
5.0
12.0
10.0
50.0
60.0
7.0
2.0
(11.6)
(13.0)
6-M4
2
1
3
4
Circuit diagram
IN OUT
LABEL
A
B
C
H
10
F
E
D
G
M4
Cover
Body
4
5
1
2
63
L1
Cx1
IN OUT
R Cx1
Cy1
Earth terminal
M4
Screw for cover
M3
A B C D E F G H
115DV0PM20042
<DV0PM20042, DV0P4220> <DV0PM20043>
105 95 70 43 10 52 5.5
145DV0P4220 135 125 70 50 10 52 5.5
165DV0PM20043 136 165 90 80 40 54 5.5
Circuit
diagram
[Size]
[Unit: mm]
[Unit: mm]
LABEL
A
C
B
H
M5
E
F
D
Earth
terminal
M4
Screw for
cover
M3
G
Cover
Body
For single phase application, use 2 terminals among 3 terminals,
leaving the remaining terminal unconnected.
7.
Conformity to EC Directives and UL Standards
Composition of Peripheral Equipments
Installation Environment
UsetheservodriverintheenvironmentofPollutionDegree1or2prescribedinIEC-
60664-1(e.g.InstallthedriverincontrolpanelwithIP54protectionstructure.)
Caution
UseoptionscorrectlyafterreadingOperatingInstructionsoftheoptions
tobetterunderstandtheprecautions.
Takecarenottoapplyexcessivestresstoeachoptionalpart.
Power Supply
100Vtype:Singlephase, 100V
+10%
to 120V
+10%
50/60Hz
(AtoC-frame)
–15%
–15%
200Vtype:Single/3-phase, 200V
+10%
to 240V
+10%
50/60Hz
(AtoD-frame)
–15%
–15%
200Vtype:3-phase, 200V
+10%
to 230V
+10%
50/60Hz
(E,F-frame)
–15%
–15%
(1)Thisproductisdesignedtobeusedinover-voltagecategory(installationcategory)
IIIofEN61800-5-1:2007.
(2)UseaninsulatedpowersupplyofDC12to24VwhichhasCEmarkingorcomplies
withEN60950.
Circuit Breaker
InstallacircuitbreakerwhichcomplieswithIECStandardsandULrecognized(Listed
and
marked)betweenpowersupplyandnoiselter.
Integralsolidstateshortcircuitprotectiondoesnotprovidebranchcircuitprotection.
BranchcircuitprotectionmustbeprovidedinaccordancewiththeNationalElectrical
Codeandanyadditionallocalcodes.
Noise Filter
Whenyouinstallonenoiselteratthepowersupplyformulti-axesapplication,consultwith
manufacturerofthenoiselter.Ifsufcientnoisemarginisrequired,connect2ltersinseries.
• Optional parts
Option part No.
Voltage specications
for driver
Manufacturer’s
part No.
Applicable
driver (frame)
Manufacturer
DV0P4170
Singlephase100V/200V
SUP-EK5-ER-6 AandB-frame
OkayaElectricInd.
7. Conformity to EC Directives and UL Standards
Composition of Peripheral Equipments
Metallic control box
Controller
Insulated power supply
for interface
Power
supply
Surge
absorber
Noise filter
Noise filter for signal lines
*1
Ground (PE)
L1
U
X4
XA
XB
X6
M
RE
V
W
L2
L3
L1C
L2C
Noise filter for
signal lines
Noise filter for
signal lines
Noise filter for
signal lines
Noise filter for signal lines
Driver
Motor
Residual
current
device
(RCD)
Circuit
breaker
*1 A to D-frame: Noise filter for signal lines, E, F-frame: Noise filter for signal lines <Power supply cable>
Option part No.
Voltage specications
for driver
Manufacturer’s
part No.
Applicable
driver (frame)
Manufacturer
DV0PM20042
3-phase200V
3SUP-HU10-ER-6
A,B-frame
OkayaElectricInd.
Singlephase100V/200V
3-phase200V
C-frame
DV0P4220 Single/3-phase200V
3SUP-HU30-ER-6
D-frame
DV0PM20043 3-phase200V
3SUP-HU50-ER-6
E-frame