B37
−−
B36
−
English
7.
Conformity to EC Directives and UL Standards
EC Directives / Conformity to UL Standards
EC Directives
TheECDirectivesapplytoallsuchelectronicproductsasthosehavingspecicfunc-
tionsandhave beenexportedto EUanddirectly soldtogeneral consumers.Those
productsarerequired to conformtothe EU uniedstandardsand to furnishtheCE
markingontheproducts.
However,ourACservosmeettherelevantECDirectivesforLowVoltageEquipment
sothatthemachineorequipmentcomprisingourACservoscanmeetECDirectives.
EMC Directives
MINASServoSystemconformstorelevantstandardunderEMCDirectivessettingup
certainmodel(condition)withcertainlocatingdistanceandwiringoftheservomotor
andthedriver.Andactualworkingconditionoftendiffersfromthismodelconditiones-
peciallyinwiringandgrounding.Therefore,inorderforthemachinetoconformtothe
EMCDirectives,especiallyfornoiseemissionandnoiseterminalvoltage,itisneces-
sarytoexaminethemachineincorporatingourservos.
Conformity to UL Standards
Observethefollowingconditionsof(1)and(2)tomakethesystemconformtoUL508C
(FileNo.E164620).
(1)UsethedriverinanenvironmentofPollutionDegree2or1prescribedin
IEC60664-1.(e.g.InstallinthecontrolboxwithIP54enclosure.)
(2)Makesureto installacircuitbreakerorfusewhich areULrecognized(Listed
marked)betweenthepowersupplyandthenoiselter.
Fortheratedcurrentofthecircuitbreakerorfuse,refertoP.B14,"DriverandList
ofApplicablePeripheralEquipments"ofPreparation.
Useacoppercablewithtemperatureratingof75˚Corhigher.
(3)Over-loadprotectionlevel
Over-loadprotectivefunctionwillbeactivatedwhentheeffectivecurrentexceeds
115 %ormore thanthe ratedcurrentbased onthe timecharacteristics(see the
nextpage).Conrmthatthe effectivecurrentofthe driver does not exceed the
ratedcurrent.SetupthepeakpermissiblecurrentwithPr0.13(Setupof1sttorque
limit)andPr5.22(Setup2ndtorquelimit).
(4)Motorover-temperatureprotectionisnotprovided.
Motorover-load-temperature protection shall be provided at the nal installation
uponrequiredbytheNEC(NationalElectricCode).
7. Conformity to EC Directives and UL Standards
EC Directives / Conformity to UL Standards
Time [s]
Overload protection time characteristics
100
115
0.1
1
10
100
200 300 400 500
Torque [%]
MSME 50 W
MSMD 50 W
MSME 100 W (100 V)
MSMD 100 W (100 V)
MHMD 100 W (100 V)
MSME 100 W (200 V)
MSMD 100 W (200 V)
MHMD 100 W (200 V)
MSME 200 W
MSMD 200 W
MHMD 200 W
MSME 400 W
MSMD 400 W
MHMD 400 W
MSME 750 W
MSMD 750 W
MHMD 750 W
MSME 1.0 kW to 5.0 kW
MDME 1.0 kW to 5.0 kW
MFME 1.5 kW to 4.5 kW
MGME 900 W to 4.5 kW
MHME 1.0 kW to 5.0 kW
Conformed Standards
Driver Motor
ECDirectives
EMC
Directives
EN55011
EN61000-6-2
EN61800-3
–
Low-Voltage
Directives
EN61800-5-1
IEC60034-1
IEC60034-5
ULStandards
UL508C
(FileNo.E164620)
UL1004-1
(E327868:50Wto750W)
UL1004
(E327868:0.9kWto5.0kW)
CSAStandards C22.2No.14 C22.2No.100
IEC
:
InternationalElectrotechnicalCommission
EN
:
EuropaischenNormen
EMC
:
ElectromagneticCompatibility
UL
:
UnderwritersLaboratories
CSA
:
CanadianStandardsAssociation
Pursuanttothedirective2004/108/EC,article9(2)
PanasonicTestingCentre
PanasonicServiceEurope,adivisionof
PanasonicMarketingEuropeGmbH