5. Protective Functions
Protective Function (What Is Error Code ?)
•
Various protective functions are equipped in the driver. When these are triggered, the
motorwillstallduetoerror,thedriverwillturntheServo-Alarmoutput(ALM)tooff(open).
• Errorstatusandtheirmeasures
•During the error status, the error code No. will be displayed on the front panel
LED,andyoucannotturnServo-ON.
•YoucancleartheerrorstatusbyAlarmclearinput(A-CLR)in120msorlonger.
•When overload protection istriggered,youcan clear it byAlarm clear input(A-
CLR)in10secorlongeraftertheerroroccurs.YoucancleartheOverloadprotec-
tiontimecharacteristics(refertoP.B36,37)byturningoffthecontrolpowersupply
betweenL1CandL2C(100V,200V)ofthedriver.
*1
•Youcancleartheaboveerrorbyoperatingthefrontpanelkeysandsetupsupport
softwear“PANATERM”.
•Besuretoclearthealarmduringstopafterremovingthecauseoftheerrorand
securingsafety.
The error code No. is displayed in the form of ErrXX.Y (X: main, YY: sub).
<List of error code No.>
Error code
Protective function
Attribute
Main Sub
History
Can be cleared
Immediate stop
11 0 Controlpowersupplyunder-voltageprotection
12 0 Over-voltageprotection
13
0
Mainpowersupplyunder-voltageprotection(betweenPtoN)
1
Mainpowersupplyunder-voltageprotection
(ACinterceptiondetection)
14
0 Over-currentprotection
1 IPMerrorprotection
15 0 Over-heatprotection
16 0 Over-loadprotection
○
*1
18
0 Over-regenerationloadprotection
1 Over-regenerationTrerrorprotection
21
0 Encodercommunicationdisconnecterrorprotection
1 Encodercommunicationerrorprotection
23 0 Encodercommunicationdataerrorprotection
24 0 Positiondeviationexcessprotection
26
0 Over-speedprotection
1 2ndover-speedprotection
27
0 Commandpulseinputfrequencyerrorprotection
2 Commandpulsemultipliererrorprotection
28 0 Limitofpulsereplayerrorprotection
29 0 Deviationcounteroverowprotection
Error code
Protective function
Attribute
Main Sub
History
Can be cleared
Immediate stop
33
0 IFoverlapsallocationerror1protection
1 IFoverlapsallocationerror2protection
2 IFinputfunctionnumbererror1protection
3 IFinputfunctionnumbererror2protection
4 IFoutputfunctionnumbererror1protection
5 IFoutputfunctionnumbererror2protection
6 CLttingerrorprotection
7 INHttingerrorprotection
34 0 Softwarelimitprotection
36
0to2
EEPROMparametererrorprotection
37
0to2
EEPROMcheckcodeerrorprotection
38 0 Over-travelinhibitinputprotection
43 0 Initializationfailure
44 0
20-bitincrementalencodersingleturncountererror
protection
45 0
20-bitincrementalencodermulti-turncountererror
protection
48 0 EncoderZ-phaseerrorprotection
49 0 EncoderCSsignalerrorprotection
87 0 Compulsoryalarminputprotection
95 0 Motorautomaticrecognitionerrorprotection
Othernumber
Othererror
Note
History
...Theerrorwillbestoredintheerrorhistory.
Can be cleared
...Tocanceltheerror,usethealarmclearinput(A-CLR).
Ifthealarmclearinputisnoteffective,turnoffpower,removethecauseofthe
errorandthenturnonpoweragain.
Immediate stop
...Instantaneouscontrolledstopuponoccurrenceofanerror.
(Settingof“Pr.5.10Sequenceatalarm”isalsorequired.)
5. Protective Functions
Protective Function (What Is Error Code ?)