Chapter 4 Settings — [POSITION] menu
112 - ENGLISH
4) Press as to select the item to adjust, and press the <ENTER> button.
f When [LINEARITY] is selected, press qw to select either adjustment method ([AUTO] or [MANUAL]).
Select [AUTO] normally.
For details of operation when [MANUAL] is selected, refer to “Adjusting to desired linearity” (x page 112).
5) Press asqw to adjust.
[CORNER/PINCUSHION]
[UPPER LEFT]
[UPPER RIGHT] [LOWER LEFT] [LOWER RIGHT]
[LINEARITY]
Horizontal direction
Vertical direction
[PINCUSHION]
[UPPER]
[LOWER]
[LEFT] [RIGHT]
Adjusting to desired linearity
1) Press as to select [GEOMETRY].
2) Press qw to select [CORNER/PINCUSHION].
3) Press the <ENTER> button.
f The [GEOMETRY:CORNER/PINCUSHION] screen is displayed.
4) Press as to select [LINEARITY].
5) Press qw to select [MANUAL].
6) Press the <ENTER> button.
f The [LINEARITY] screen is displayed.
7) Press asqw to adjust.
Note
f The menu, logo, or waveform monitor display may run off the screen when [GEOMETRY] is set.
f If [EDGE BLENDING] (x page 115) adjustment and [GEOMETRY] are used together, correct edge blending adjustment may not be
possible in certain environments.
f The optional Upgrade Kit (Model No.: ET-UK20) can be used to expand the correctable range. To purchase the product, consult your dealer.
f The [GEOMETRY] setting is disabled in the following cases, and the geometric adjustment function cannot be used.
g When the [ADVANCED MENU] menu → [QUAD PIXEL DRIVE] is set to [OFF]
g When the [DISPLAY OPTION] menu → [SIMUL INPUT SETTING] is set to anything other than [OFF]
f The image may disappear for a moment or may be disrupted while performing adjustment, but it is not a malfunction.