EasyManua.ls Logo

Panasonic PT-VZ575N

Panasonic PT-VZ575N
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When WEB Control administrator rights password is not set (Non-protect mode)
Connection method
1) Obtain the IP address and port number (Initial set value = 1 024) of the projector and make a request
for connection to the projector.
f Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page.
IP address :
Obtain from main menu → [NETWORK/USB] → [STATUS]
Port No. :
Acquire from the WEB control → [Detailed set up] → [Command port set up] page
2) There is a response from the projector.
r Response data
Data section Blank Mode Termination symbol
Command
example
“NTCONTROL”
(ASCII string)
0x20
‘0’
0x30
(CR)
0x0d
Data length
9 bytes 1 byte 1 byte 1 byte
fMode : 0 = Non-protect mode
Command transmission method
Transmit by the following command format.
r Transmitted data
Header Data section Termination symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
1 byte 1 byte Undened length 1 byte
r Receive data
Header Data section Termination symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
1 byte 1 byte Undened length 1 byte
r Response data
String Details Termination symbol
Message
"ERR1" Undened control command
(CR)
0x0d
"ERR2" Out of parameter range
"ERR3" Busy state or no-acceptable period
"ERR4" Timeout or no-acceptable period
"ERR5" Wrong data length
"ERRA" Password mismatch
Data length
4 bytes
1 byte
138 -
ENGLISH
Chapter 7 Appendix - Technical Information

Table of Contents

Related product manuals