How to use different-diameter-tube joint (supplied)
1)  When using with single connection
 •OutdoorPZ3andPZH3series(Type60)
Liquid tube (ø6.35)
Connect the gas socket tube A (ø12.7 - ø15.88) 
to the gas tubing side indoor unit
Connect the liquid socket tube B (ø6.35 - ø9.52) 
to the liquid tubing side indoor unit
Gas tube (ø12.7)
The following examples show the multiple connections.
●   
Connectable or disconnectable units vary depending on a series of outdoor units. Refer to 
the installation instructions for the outdoor unit as well.
●   
 Two, three or four indoor units can be operated simultaneously with a single remote controller.
   Note that individual operation is not possible.
●   
 Master unit and slave unit can be set automatically in twin, triple and double twin system.
   No address setting is necessary.
5-2. Connecting Tubing Between Indoor and Outdoor Units 
(1)  Tightly connect the indoor-side refrigerant tubing extended from the wall with the outdoor-side 
tubing.
Indoor Unit Tubing Connection
Unit : mm
Indoor unit type S-25, 36, 50PY3E S-60PY3E
Gas tube  ø12.7 ø15.88 (ø12.7)
Liquid tube ø6.35 ø9.52 (ø6.35)
Different-diameter-tube joint for the indoor unit tubing connection part is supplied with 
S-60PY3E. 
The size of parenthesis indicates the connection tube diameter when using the different-
diameter-tube joint.