26
7 Self-Diagnostic and Special Mode Setting
7.1. Special Mode Table 1
Self-Diagnostic Function provides information for error to service personnel by Self-Diagnosis Display when any error has occurred.
U**, H** and F** are stored in my memory and held.
You can check latest error code by transmitting [0] [1] of Remote Control in Service Mode.
Automatic Display on FL will be cancelled when the power is turned off or AC input is turned off during self-diagnosis display is
ON.
Item
FL display
Key operation
Mode name Description Front Key
Initialize Mode *A
1) Unit power-up
2) FL shows "Hello" then "goodbye"
3) Unit power-down
4) Unplug & plug AC Cord
ll the main unit’s parameters are initialized.
Press & hold [VOL+], [OPEN/
CLOSE] follow by [POWER]
button in sequence during
power off.
Press & hold [VOL+], [OPEN/
CLOSE] & [PLAY] on main
unit for 3S or more during
power off.
Rating password
The audiovisual level setting password is ini-
tialized to Level 8.
Service Mode Setting every kind of modes for servicing.
*Details are described in 7.3.1. Service Mode
at a glance.
BD-ROM history cleaning < Persistent Storage> of BD-ROM standard is
cleaned.
Screen display: [The player’s history data has
been cleared] is displayed for five seconds.
Same display as before
execution.
When power on press [STOP] on
main unit & [POWER] on remote
control.
When power is off, press [SKIP
FWD] on remote control & [OPEN/
CLOSE] key on main unit
simultaneously for 5 seconds
or more.
Forced disc eject Removing a disc that cannot be ejected.
The tray will open and unit will shift to P-off
mode.
While Demonstration Lock is being set, this
Forced disc eject function is not accepted.
The display before
execution leaves.
Forced power-off When the power button is not effective while
power is ON, turn off the power forcibly.
Display in P-off mode. P
seconds.
ress [POWER] over than 10
Aging Perform sequence of modes as * Aging
Description shown below continually.
Display following the mode. When the power is ON, press
5
seconds and less than 10 seconds.
NOTE1:
If Unit has not turned into Aging
mode by operations shown above,
execute TEST MODE once and re-
execute operation shown above.
(*All the main units parameters
include tuner are initialized by
TEST
mode.)
NOTE2:
If the unit has hung-up because of
pressing keys for over 10 seconds,
once turn off the power, and re-exe-
cute this command.
*When releasing Aging mode, press
[POWER] key over 10 seconds.
-----------
INITINIT
SERV
************
******
[SKIP FW], [PLAY] & [OPEN/
CLOSE] simultaneously for over
Press [SKIP REV] on remote
control, follow by [PLAY] on main
unit simultaneously for five
seconds when power-on.

Table of Contents