29
7.3.2. Error Code Table 2 (For BD)
7.3.3. Error Code Table 3 (Power Supply & Digital Amplifier)
SELF
CHECK
Restoration operation Since the power cord fell out during a power
failure or operation, it is under restoration
operation.
*It will OK, if a display disappears automati-
cally. If a display does not disappear, there is
the possibility that defective Digital P.C.B. /
DVD drive.
No display
PLEASE
WAIT
Unit is in termination process Unit is in termination process now.
BYE is displayed and power will be turned off.
No display
UNFOR-
MAT
Unformatted disc error You have inserted an unformatted DVD-RAM
or DVD-RW that is unformatted or recorded
on other equipment.
The disc is not
formatted properly.
No PLAY When there is a viewing restric-
tion on a BD-Video or DVD-
Video.
Rating password is set. No display
Error Code Diagnosis contents Description Monitor Display Automatic FL display
SELF CHECK
PLEASE WAIT
UNFORMAT
No PLAY
The character indication flows
sideways.
Error
Code
F61 The abnormalities In normal operation, when DCDET2 goes Press [ STOP] on main
in an output or power to "L" (Low) (Not during POWER OFF unit for next error.
supply circuit of condition), F61 appears on FLDisplay
POWER AMP for 1 second and PCONT goes to
"L" (Low).This is due to speaker output
has DC voltage or fan is not working.
F76F76
H19
Abnormality in the
Fan Unit & its
circuitries
In normal operation when DCDET1 is
Fan Unit is not operating properly
Press [ STOP] on main
output voltage of detected "L" (Low) for two consecutive unit for next error.
stabilized power times, F76 is displayed on FL for
supply 1 second and after that PCONT will be
turned to "L" (Low). This is due to any of
the DC voltages (+9V, +7V, -7V, +5V,
+5.3V etc.) C22 not available.
Diagnosis Contents Description of error Automatic FL Display Remarks
Press [ STOP] on main
unit for next error.