36
TH-65PF12EK
10.1.2. Initialization Pulse Adjust
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 and adjust VR16601 for 250V ± 10V.
10.1.3. P.C.B. (Print Circuit Board) exchange
10.1.3.1. Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
10.1.3.2. Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
*See the Panel Label.
Caution
Absolutely do not reduce Vsus voltage below Ve not to damage the P.C.B.
Test Point Volume Level
TPSC1 (SC) VR16601 (SC) 250V ± 10V
at 100
µs period on the down slope.
P.C.B. Name Test Point Voltage Volume Remarks
P Board Vsus TPVSUS (SS) Vsus ± 2V VR251 (P) *
SC Board Vad TPVAD (SC) -155V ± 2V VR16600 (SC)
Vscn TPVSCN (SC) Vad_base:+145V±4V
GND_base: -10V±6V
Fixed
Vset TPVSET (SC) 290V ± 9V Fixed
SS Board Ve TPVE (SS) Ve ± 2.5V Fixed *
D, DS, DN Board White balance and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board Set Market Select Number to correct destination by MS mode (See chap. 6.1.5)

Table of Contents