130
[Screenshot 5]
The format check screen appears.
, Press the arrows button (A and B) to move the cursor
to "EXECUTE" and press the [SET] button.
→ Mirroring starts and the top page of the disk configu-
ration menu resumes.
● Cancel of mirroring
You can cancel the mirroring function by following the pro-
cedure below.
z Turn on this unit and press the [SET] button after com-
pletion of system check.
Note: If the hard disk is taken out, the top page of the
disk configuration menu automatically appears.
[Screenshot 1]
The top page of the disk configuration menu appears.
x Press the arrows button (A and B) to move the cursor
to "Mirror OFF" and press the [SET] button.
[Screenshot 2]
A message to confirm mirror cancellation appears.
c Press the arrows button (A and B) to move the cursor
to "OK" and press the [SET] button.
→ The mirroring function is canceled.
Note: One of two hard disks that consist of mirroring is
marked with "* (capacity)" on the top page of the
disk configuration menu after mirror cancellation.
● Hard disk recovery
In case that one hard disk fails while the mirroring function
works or other cases, you can set the disk so that the faulty
disk will be recovered after hard disk replacement.
z Turn on this unit and press the [SET] button after com-
pletion of system check.
Note: If the hard disk is changed or taken out, the top
page of the disk configuration menu automatically
appears.
[Screenshot 1]
The top page of the disk configuration menu appears.
x Press the arrows button (A and B) to move the cursor
to "Mirror ON" and press the [SET] button.
[Screenshot 2]
A message to confirm mirror recovery appears.
c Press the arrows button (A and B) to move the cursor
to "OK" and press the [SET] button.
Hard disk recovery is executed during operation after
exiting from the disk configuration menu.