66 Programming Guide
WinLoad / BabyWare
Monitoring Phone #
Communicator
Cancel Communication
Step Action Details
1
+ [
INSTALLER CODE] = flash.
2
3 [9]
4 [
PHONE #] + [ENTER]* Enter PC phone # (up to 32 digits) and press [ENTER].* To erase WinLoad / BabyWare
phone #, panel ID, and PC password, press the [SLEEP] key for 3 seconds.
5 [
PANEL ID] Enter 4-digit Panel ID
6 [
PC PASSWORD] Enter 4-digit PC Password
Step Action Details
1
+ [
INSTALLER CODE] = flash.
2
3 [1]
4 [
PHONE #] + [ENTER]* Enter monitoring station phone # (up to 32 digits) and press [ENTER].* To erase monitoring
phone #, reporting format, and account #s, press the [SLEEP] key for 3 seconds.
5 [PARTITION 1 ACCOUNT #]
6 [1] = CID
[2] = SIA NOTE: SIA is not supported with GPRS/IP reporting
7 [
PARTITION 2 ACCOUNT #]
Step Action Details
1
+ [
INSTALLER CODE] = flash. [MAINTENANCE CODE] may also be used, however, it cannot modify the
backup phone number.
2
3 [2] = Backup Phone #
[3] = Personal Phone #1
[4] = Personal Phone #2
[5] = Personal Phone #3
[6] = Personal Phone #4
[7] = Personal Phone #5
[8] = Pager #
4 [
PHONE #] + [ENTER]* Enter phone # (up to 32 digits) and press [ENTER]. Goes to next phone#, or go to step 5 if
[8] = Pager # was selected. To erase a phone number pager message, press the [SLEEP]
key for 3 seconds.
5 [
MESSAGE] + [ENTER] Step 5 for Pager # only. Enter pager message and press [ENTER].
Step Action Details
1
+ [
INSTALLER CODE] = flash. [MAINTENANCE CODE] may also be used.
2
3 [9] Cancels all communication with WinLoad / BabyWare / GSM module.

Other manuals for Paradox Spectra SP4000